6. Remove the 9 machine screws that secure the power supply/amplifier assembly to the
frame. Three are located above the heat sink, three are located below and three are located
near the center of the heat sink. See below. note that when the array module is mounted on
the wall, you will first need to rotate it 90 degrees to gain access to the screws.
7. Move the assembly slightly toward the top of the module and then carefully lift the
assembly out through the side of the cabinet. Note that when the array module is mounted
on the wall, you will need to lift the assembly up slightly before sliding it out.
8. Reverse the procedure to install the replacement assembly.
9. Set the address dip switches of the new assemby to the same address as the assembly
being replaced.
Owners Manual
RH 572 Rev D 24/06
19201 Cook Street, Foothill Ranch, CA 92610, USA . Phone: +1 949 588 9997 . Fax: +1 949 588 9514 . [email protected] . www.renkus-heinz.com
48