Connecting the APCA-45
Connect the two standard and one optional
Ø4.0 mm (0.16 in) air pipes to the connectors on
the back of the unit (see “Installation” diagram on
page 19). Also connect the M12 connector to the
mating cable (not supplied).
For more information see “Pneumatic options” on
pages 13 to 18.
Mounting the APCA-45 to the machine
1. Mount the APCA-45 to fitting location using
4 × M4 screws (supplied). Leave the screws
semi-tight.
2. Set APCA-45 base perpendicular to the
mounting face, the gap will be approximately
1 mm (0.04 in). Torque all four screws to
2.60 Nm to 2.70 Nm (1.92 lbf. ft. to 1.99 lbf ft).