6
Specification
(continued)
Output connection
Blanked DIN EN ISO 228–G 1/8 outlet for customer configurable
“air blast stalk”.
Mounting
M4 × 50 mm (1.97 in) long (ISO 4762 grade 12.9) or equivalent × 4
Retract confirm sensor
Operating voltage 12 Vdc to 30 Vdc, no load current 3 mA, rated
operating current 150 mA, output resistance open collector,
switching output PNP normally open (NO). When the cover is
extended, the output is LOW. When the cover is retracted it is
HIGH. (12 Vdc to 30 Vdc).
Sealing
IPX6 and IPX7, BS EN 60529:1992+A2:2013
(IEC 60529:1989+A1:1999+A2:2013)
Connector sealed to IP67 when mated.
Storage temperature
–25 °C to +70 °C (–13 °F to +158 °F)
Operating temperature
+5 °C to +55 °C (+41 °F to +131 °F)
Note 1
When wiring the APCA-45 to the machine control the installer should ensure the screen is connected (see pages 10 and 11).
Note 2
Performance specification is tested at a standard test velocity of 480 mm/min (18.9 in/min). Significantly higher velocity is
possible depending on application requirements.
Note 3
Using a 60 mm stylus.
Note 4
Can be configured by customer to provide air blast functionality.