![Renault ZOE 2013 Technician Manual Download Page 14](http://html1.mh-extra.com/html/renault/zoe-2013/zoe-2013_technician-manual_1439775014.webp)
Renault ZOE - Roadside assistance technician's guide
RENAULT PROPERTY
Network Development | Version 2.1 | 11 January, 2013
14
a.
Individual protective equipment for repairs
For any operation on a vehicle which has been damaged in an accident, the following must be worn:
•
a face shield,
•
electrical safety gloves of the correct size.
Electrical safety gloves
Insulating gloves for electrical work, class 00, test voltage 2500V,
operating voltage 500V.
Class III personal protective equipment, in accordance with the
following standards:
European:
EN 60 903
International: CEI 60 903
Front screen
Protects the face against projections of liquid/solid and
short circuit electric arcs.
Personal protective equipment in accordance with European
standards:
EN 166: personal eye protection, specification.
EN 170: personal eye protection, UV filter.
No-voltage tester (NVT)
The absence of voltage is measured using a measuring instrument.
No-voltage tester (NVT)
The measurement is made between the metal chassis of the
and the conducting core of the damaged orange 400V cables.
This device must comply with the following standards:
European:
EN 61 243-3
International: CEI 61 243-3