5.3 Hygiene function/
legionella circuit
You have the option of activating a hygiene func-
tion.
The hygiene function can only be performed with
an active additional heat generator, e.g. with a
REMKO Smart-Serv auxiliary heat generator.
This hygiene/legionella function can be activated
on a static basis, i.e. always on the same weekday
at the set time.
The "Static" operating mode is possible without
flow sensor. The hygiene function is purely acti-
vated after a time program. To do so, you must set
the day and time as well as the desired tempera-
ture.
You can also activate a dynamic hygiene function
that is aligned with your requirement and storage
tank capacity.
The precondition for the dynamic hygiene function
is that a REMKO flow sensor (e.g. EDP no.
254070) has been installed. The dynamic hygiene
function can be individually adjusted to the user
and the installed storage tank size.
Activation of the hygiene function is only possible
in the expert level. Accessing the expert level is
described in chapter
The hygiene function is not activated ex works. In
order to install this function, select the following
parameters consecutively in the expert level:
Expert level
¯
Settings
¯
Basic settings
¯
System configuration
¯
Hygiene function
(OFF)
¯
Static
Dynamic
After selecting the function, the hygiene function is
enabled and can be adjusted in the "Settings" level
under the point "Hot water". You can find the
description for activation and setting in the fol-
lowing.
Parameter settings for the hygiene function
In order to access the setting parameters for the
hygiene function, select the following parameters
consecutively:
Expert level
¯
Settings
¯
Hot water
¯
Hygiene function
¯
Static
Dynamic
Set temperature
Day of activation
-
Time of activation
-
-
Inspection time
-
Storage tank volume
-
Pulse valency
Max. duration until cancellation
Circulation pump
2nd heat generator
95