1. Level
2. Level
3. Level
°
CXX
External heating
EFXX
External fan
SIXX
Service interval
tESt
Self-test
rHXX
“Value”
"Value confirmed"
“Value confirmed"
“Value confirmed”
OK
“Value confirmed”
“Test confirmed”
“Value”
“Value”
“Value”
OK
OK
OK
OK
OK
OK
OK
OK
Menu structure of the SLN air dehumidifier
Menu items
Code: RH
The code “RH” stands for
the relative air humidity that
the unit should reach. The value
can be set between 40 and
99 % RH. The default value is 60.
Code: EF
The code “EF” stands for external
heating control with the aim of
reaching the specified air humidity
more quickly. The set value may
differ from the setpoint humidity
so that the external heating can
either operate permanently or
merely provide a support function.
The value can be set between 40
and 99 % RH. The default value is
set to “OF” in this case.
Code: SI
The code “SI” stands for
themaintenance interval that
the operator or fitter requires.
Thisvalue is indicated in weeks
and can be set from 01 to 99.
Thedefault value is “OF.”
Code: tE
The code “tE” stands for testing
and the value “St” for self-test.
To start the self-test, press “OK”
and to cancel it, hold the down
key down for 5 seconds.
Menu structure
To define the setpoints using
theintegrated operator panel, hold
down the “OK” key for 5 seconds
so that the display switches from
the humidity currently measured
to the menu item rHXX.
If you would like to exit
the menu, do not press any
keys on the operator panel for
10 seconds.
NOTE
The corresponding terminals
for these options are located on
the control board of the unit.
Code: °C
The code “°C” stands for external
heating control with the aim
of reaching a defined setpoint.
The value can be set to between
05 and 34. This value is set to
“OF” by default.
14
REMKO SLN Series
Summary of Contents for SLN 45