Duct interface found in the wall
opening.
■
Secure the wall spacers provided
with the unit to the bottom
corners of the unit using
adhesive.
■
Affix the wall-mounted bracket
to the wall in the adjacent room
and hang the unit on it.
■
The unit is connected to
the duct interfaces that are
already mounted on the wall
by way of the self-sealing profile
lips on the unit connection
fittings.
min. 403
min. 225
700
min. 225
110
290
110
min. 730
178
Location of the wall-mounted bracket using the example of the unit SLN 65
395
Condensate water drain
The condensate water drain is
located on the unit's base.
The condensate drainage is
connected to the discharge nozzle
supplied.
A solid or flexible ½” discharge
connector can be installed on this.
■
The discharge hose must always
be laid at an incline of at least
2 % so that the water can flow
unhindered from the drip tray.
■
Alternatively, a condensate
pump can be fitted to the unit
in order to pump the condensate
water to a drainage point
located at a higher level.
■
If drainage is to be carried out
through the wall, the relevant
measures such as holes for
correct condensate drainage
must be taken before installing
the unit.
■
See the diagram at the side for
information on the location
of the drainage connection.
Access to the controller
Remove the front plate after
opening the lock on the underside.
Lift the cover vertically upwards
and then pull away from the unit
horizontally.
The controller is located behind
the top cover of the internal
housing parts above the
compressor.
The controller is accessed
by removing the 2 screws on
the front of the internal housing
parts.
■
The unit must never be
mounted in the immediate
vicinity of heaters or other
sources of heat.
■
The room being dehumidified
must be closed to
the neighbouring atmosphere.
■
Avoid having opened windows
and doors etc., and avoid
frequent entry to or exit from
the room as much as possible.
■
In order to achieve optimum
room air circulation using
the dehumidifier, the supply
and exhaust air openings must
remain clear.
All measurements in mm
Detailed information
on the wall-mounted
bracket
All measurements in mm
Location of the condensate drain
56
430
11