THERMOJET
®
H-2000E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740121
Rev
15
Date
June 2020
Page
31
of
102
Wait a maximum of 2 minutes for the oil pump to establish oil flow and pressurize the inlet
system. As oil flows into the pump, system pressure will build and be indicated on the filter inlet
and filter discharge pressure gauges located above door. If pressure does not build and no oil is
flowing, trace the inlet piping for blockages such as a closed valve. If the oil path is free from
obstructions, manually prime the pump and the inlet piping. Ensure that the suction line distance
is within the allowable limit as mentioned in INSTALLATION Section of this manual
NOTICE:
Wear appropriate personal protective gear.
When cleaning oil spills consult with your
lubricating oil supplier and the lubricating oil MSDS
documentation regarding safe guards and
Personal Protective Equipment (PPE)
requirements
Observe pressure gauges to verify
that oil is flowing into the ThermoJet
Oil Purifier.