Receipt Inspection
Remove all shipping materials and plastic plugs.
Inspect for shipping damage externally and internally (open enclosure door), and immediately
report any damage found to the delivering freight company. It is desirable to take photographs of
any damage to substantiate your claim.
Inspect for completeness of materials and equipment against the packing list and the purchase
order. If you believe there are discrepancies, notify manufacturer.
Placement of Equipment
Locate the Thermo
Jet
Oil Purifier as close as possible to the oil reservoir in an upright position.
For base mounted units verify the adequacy and strength of all relevant supporting surfaces, See
Dimensional Drawings in the PARTS LIST / DRAWINGS / SCHEMATICS section of this manual
for anchor bolt and equipment clearance dimensions
The base mounted ThermoJet Oil Purifier is constructed with lift rings to assist in equipment
placement. Ensure that lifting equipment and rigging is suitable for safely lifting, moving and
placing the equipment.
Using standard plant practices secure the ThermoJet Oil Purifier to the installation surface by
bolting the four (4) mounting feet.
NOTICE:
Be sure to leave working space around the system and consider
space requirements for electric heater removal, fully opened access
door, control panel enclosure door, and gauge monitoring.
Do not tip or stand equipment on edge
WARNING
Use suitable transport equipment for lifting and
setting the equipment into place. Ensure that the
equipment is secured prior to and during lifting
and transport. Stand clear of the all equipment
while being maneuvered. Crane and fork truck
operators should be properly trained in there
operation.