Separation Vessel Maintenance
The ThermoJet Oil Purifier must be shut down before performing separation vessel. This
maintenance operation involves removing the separation inspection cover plate and cleaning the
interior of the separation vessel. The inspection cover plate is located on the interior of the
ThermoJet Model H2000E console cabinet.
First shut down the ThermoJet. See the section titled
Shut Down Procedures
on how to turn the
ThermoJet Oil Purifier OFF.
Close and tag the nearest oil block valve to the ThermoJet oil inlet and outlet connection.
First drain all oil from the separation vessel and the inlet oil filter. A drain plug is located in the
outlet pump suction line between the separation vessel outlet and the pump suction for draining
the separation vessel. Use the drain valve located at the bottom of the inlet oil filter vessel for
draining the oil filter. For additional information on draining the oil from the oil filter see the section
in this manual titled
Oil Filter Maintenance
.Use a pail to gather the oil. See the sections of this
manual titled
Cleaning and Decontamination
and
Removal from Use, Disposal and Transport
for
additional information.
WARNING
Surfaces and contents are HOT. Once the
system has been shut down allow sufficient time
for cooling before servicing this equipment.
Oil filter drain valve
Clean out cover
Separation drain plug