THERMOJET
®
H-2000E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740121
Rev
15
Date
June 2020
Page
36
of
102
System Discharge Pressure
No adjustments are necessary to the discharge pressure. Once the pressurized oil is processed
through the ThermoJet Jet Mixer it enters the separation vessel where the air and removed water
vapor is vented out of the system. The return oil pump takes the processed oil from the
separation tank and returns it to the equipment reservoir or bulk oil supply tank being serviced.
System pressure on the return oil circuit is maintained by a check valve set at 50 PSIG (3.4 BAR).
Return oil pressure can be monitored by observing the System Discharge pressure gauge.
A pressure relief valve is installed on the in the return oil circuit before the check valve. The relief
valve is factory set at 270 PSIG (18.6 BAR). If the oil pressure will not reach 50 PSIG (3.4 BAR)
the relief valve may have operated and opened. See the trouble shooting section of this manual
for additional information.
Pressure relieve valve prevents
over pressure
Check valve maintains system return oil
pressure
Outlet oil pressure is monitored by
observing the System Discharge pressure
gauge