THERMOJET
®
H-2000E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740121
Rev
15
Date
June 2020
Page
56
of
102
Once electrical power has been removed and locked out from the unit, open the electrical
terminal enclosures for the oil heater and disconnect the power wires from the terminals. Remove
the cap from the first conduit elbow adjacent to the heater enclosure and pull all of the conductors
through the conduit so that they are out of the way of the conduit union. Loosen the conduit union
and separate the two halves of the fitting so that the heater bundle can be removed.
the fitting so that the heater bundle can be removed.
WARNING
Use suitable transport equipment for removing the
heater bundle from the heater vessel, lifting and
re-installing the heater into the heater vessel.
Ensure that the heater is secured prior to and
during lifting and transport. Stand clear of the all
equipment while being maneuvered. Crane and
fork truck operators should be properly trained in
there operation.
Heater approximate weight is 185 pounds (84 Kg)
Oil heater terminal enclosure
Remove the cap from the elbow and
pull the conductors through the fitting
Conduit union