System Vent Operation
No adjustment is necessary for operation of the vent system discharge. Once the system is
operating and air begins to enter the separation tank it is vented to atmosphere.
To accommodate any condensate removed by the ThermoJ
et
while air and water vapor are
exhausting, a liquid drainer is furnished to route the condensate to the condensate purifier
assembly. The excess oil is removed from the condensate and the water is properly routed to the
sewer system.
The discharge from the Condensate Purifier
Assembly may be contaminated with the substances
being removed from the processed oil. Ensure that
the methods used to manage and dispose of these
materials are in compliance with all governing
authorities and plant policies and procedures.
Exhaust vents to atmosphere after
passing through coalescing filter. [Vent
exhaust away from personnel]
A liquid drainer routes the condensate
to the condensate purifier assembly
Condensate purifier assembly
discharge is routed to oily water
collection.