installation
Wiring Diagram with Optional Wall Thermostat
If any of the original wires as supplied with the appliance must be replaced, it must be replaced with CSA type SEW (200
o
C) or its equivalent.
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will
continue to operate as long as there are 4 AA batteries installed. However, a 120V A.C. power supply is needed for the fan/blower/lights operation.
This heater does not require a 120V A.C. supply for
operation. In case of a power failure, the remote
control/thermostat will continue to operate as long
as there are 4 AA batteries installed.
CAUTION:
Ensure that the wires do
not touch a hot surface and are away
from sharp edges.
WARNING:
Electrical Grounding
Instructions
This appliance is equipped with a
three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not
cut or remove the grounding
prong from this plug.
Note:
4 AA Batteries must be installed into the back
up battery compartment however for this unit to
operate when power is lost. See battery back up
instructions in this manual The fan and or lights
will not operate during a power outage.
GM8K1-N
911-373
REMOTE OVERRIDE
TOGGLE SWITCH
911-314
WIRE
911-391
WIRE
911-393A
SPARK
MH3V
VALVE
911-380 NG
911-381 LP
TX580 REMOTE
911-387
BATTERY
PACK
911-395
MAIN
LINE
AC
3 METER
CORD
911-245
WIRE HARNESS
FAN
911-389
RC500EX WIRING DIAGRAM
6.40 x 3.95”
DC 6V
ADAPTER
911-394
FUSE
1A / 250V
5x20 mm
RED
ORANGE
BLACK
GREEN
GREEN
BLACK
BROWN
BROWN
RED
AUX300
911-365
PILOT
911-396 NG
911-397 LP
FLAME DETECT
GROUND
AA
AA
AA
AA
LIGHTSHIELD RC500
366-108
WIRE HARNESS
LIGHTS
911-390
GROUND
WHITE
GREEN
WHITE
WHITE
WHITE
WHITE
BLACK
BLACK
BLACK
BLACK
BLACK
WIRE 4 POS IFC FAN & LIGHT
911-177
FAN
910-215/P
BLACK
BLACK
GROUND
BLACK
WHITE
OPTIONAL
THERMOSTAT
A wall thermostat may be installed if
desired. Connect the wires as per the wiring
diagrams.
Note: Preferable if the thermostat is
installed on an interior wall.
Regency® offers an optional programmable
thermostat but any 250-750 millivolt rated non
anticipator type thermostat that is CSA, ULC or UL
approved may be used.
CAUTION
Do not connect the millivolt wall
thermostat wires to the 120V
wires
.
10'/
911-389-ASM