60
|
RC500EX
maintenance
Accent Light Bulb
Replacement
1. Turn off stove and allow to return to room
temperature.
2. Shut off electrical supply and lift off cast top.
6. EV1,EV2, ground wires, and the stepper motor
also need to be disconnected prior to removal
of the valve
7. Carefully lift the valve tray assembly up and out
of the unit to remove.
8. Replace with new valve assembly and reverse
steps to reinstall.
Valve Assembly Replacement
If the valve requires maintenance or replacement,
use the following instructions:
Note: Always close off the gas and
electrical supply before removing
the valve.
1. Open the front door of the unit.
2. Remove front grill (see instructions in this
manual).
Note: Use a magnetic type screwdriver if
possible.
5. Remove 8 screws to remove valve tray.
ttoooollttiipp
3. Remove 1 screw from the cover of each light
assembly housing in locations shown below.
4. Remove 2 screws to release each bulb housing.
tooltip
Glass Gasket
If the glass seal on the appliance requires
replacement a graphite seal specifically designed
for this appliance is required. Front Glass Part #
is 936-271 with 6ft. required. These are applied
with self adhesive tape. On the inner glass only,
there are also white ceramic papers installed in
front of both the side and front glass.
Inner side glass paper Part # 366-074 (Each)
Inner Front glass paper Part # 366-075.
There is also gasket installed on each side of the
outer glass to protect against breakage when
installing the glass. Gasket part number is 936-238.
3 feet in total is required to complete both sides.
Gasket is sold per foot.
Glass
Your Regency
®
fireplace is supplied with high
temperature 5mm-Ceramic outer glass and
inner glass. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all
product warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the
glass front or with a cracked or broken
glass front.
* Wear gloves and safety glasses when removing
damaged or broken glass.
* Replacement of the glass panels should be
done by a licensed or qualified service per
son.
Glass Replacement
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass is shipped
already installed into the door frame. Reinstall as per
Glass Installation in the "Glass Installation" section.
REPLACEMENT GLASS:
RC500EX
Front Safety Glass- Tempered (Part#197067/P)
Side Outer Tempered Glass - Ceramic (Part#
197072/P)
Side Inner Glass - Ceramic (Part# 940-504/P)
See Glass replacement instructions in this
manual.
Push the pipe sections completely together, the
minimum pipe overlap is 1-1/4". Secure all outer
pipe joints by using at least two screws. Locate the
screws at the bottom of the pipe so that the screw
heads are hidden on the final installation.
NOTE: For best results and optimum perfor-
mance with each approved venting system,
it is highly recommended to apply “Mill-Pac”
sealant (supplied) to every inner pipe connec-
tion. Failure to do so may result in drafting
or performance issues not covered under
warranty.
Vent Reassembly /
Replacement
Top of Unit
5. Replace bulb(s) as required.
Note:
Do not touch bulb with bare hands, use
gloves or a tissue to handle bulb.
6. Reverse steps to reassemble.
3. Remove media from burner (logs, glass, and
volcanic stones)
4. Remove burner (see instructions in this manual).
N/S 936-271 Glass Gasket Tadpole Tape 1 1/2
(Sold Per Foot) (6 Feet required)
N/S 366-074 Lyatherm White Gasket Inner
Side Glass (Each)
N/S 366-075 Lyatherm White Gasket Inner
Front Glass
N/S 936-238 Outer Side Glass Gasket (Sold
Per Foot)
N/S 366-549 Glass Clips/Screws Complete