RC500EX
|
33
installation
Horizontal Venting with Two (2) 90
o
Elbows
Horizontal Venting with Two (2) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
H
H1
V
H1
H
V
One 90
o
elbow = Two 45
o
elbows.
Option
V
H + H1
With these options, maxi
-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum
1 foot between 90
o
elbows is required.
A)
2' Min.
4' Max.
B)
3' Min.
5' Max.
C)
4' Min.
6' Max.
D)
5' Min.
7' Max.
E)
6' Min.
8' Max.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the
"Vent Restrictor Position" section.
Option
H
V
H + H1
With these options, max.
total pipe length is 30 feet
with min. of 8 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1
foot between 90
o
elbows is required.
A)
1' Max. 1' Min.
3' Max.
B)
2' Max. 2' Min.
5' Max.
C)
3' Max. 4' Min.
6' Max.
D)
4' Max. 6' Min.
7' Max.
E)
5' Max. 8' Min.
8' Max.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the "Vent Restric
-
tor Position" section.