Clearances to Combustibles
The clearances listed are MINIMUM distances.
Measure the clearance to both the appliance and
the chimney connector.
The farthest distance is
correct if the two clearances do not coincide.
For example, if the appliance is set as indicated in
one of the figures but the connector is too close,
move the stove until the correct clearance to the
connector is obtained.
This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type of
installation with another in order to achieve
closer clearances.
This unit can be installed on a solid combustible
surface like a wood floor. This unit can also be
installed directly on carpeting or vinyl.
Use the minimum clearances shown in the dia
-
grams below:
RC500EX Clearances
A
Left/Right Side Wall to Unit
*
9" / 229 mm
B Back Wall to Unit
2" / 50mm
C Vertical Vent Pipe
to Back Wall
2" / 50 mm
D Wall to Centerline of Pipe 8-3/4"/222 mm
E Unit Corner to Wall (Top Vent) 4" / 50 mm
Unit Corner to Wall (Rear Vent) 5-3/4"/146 mm
F Alcove Width 50" / 1270mm
G Alcove Depth 36" / 914mm
H Minimum Ceiling from top of unit 15" / 381mm
*IMPORTANT
If installed in an alcove the clearance on one side
must be a minimum of 9 inches. The other side
would need to be a minimum of 21 inches as a
result of the clearance being 50 inches in length
when installed in an alcove.
If the minimum of 9 inches is increased on one
side, the other side could be decreased if the alcove
was 50 inches.
**20'
E
C
D
A
F
B
12'
Max.
Locating Your Gas Stove
When selecting a location for your stove, ensure
that the clearances listed above are met as well
as ensuring that there is adequate accessibility for
servicing and proper operation.
See complete details in this manual.
Manufactured Mobile Home
Additional Requirements
1. Ensure that structural members are not cut or
weakened during installation.
2. Ensure proper grounding using the #8 ground
lug provided.
3. Appliance must be anchored to the floor
with the supplied anchoring methods.
Combustion and Ventilation Air
The combustion air from this appliance is drawn
from outside the building through the outer flue.
Extra provision for combustion air inside the
room is not required.
A) Cross Corner
B) Room Divider
C) Island
D) Flat on Wall
E) Flat on Wall Corner
F) Flush with Wall/Alcove
For Vent Termination requirements, see "Exterior
Vent Terminal Locations" section.
**Maximum length will vary depending on vent run.
F
Left Side Wall
Right Side Wall
Horizontal
F
Pipe
Left Side Wall
Right Side Wall
Vertical
Pipe
D
G
H
Flue Pipe Clearances to
Combustibles
Horizontal top = 3"
Horizontal sides = 2"
Horizontal bottom = 2"
Vertical =
2"
Passing through wall/floor/ceiling
when fire-stop is used = 1-1/2"
Accent Light Bulb Install
1. Turn off stove and allow to return to room
temperature.
2. Shut off electrical supply and lift off cast top.
ttoooollttiipp
3. Remove 1 screw from the cover of each light
assembly housing in locations shown below.
4. Remove 2 screws to release each bulb housing.
Top of Unit
5. Replace bulb(s) as required.
Note:
Do not touch bulb with bare hands, use
gloves or a tissue to handle bulb.
6. Reverse steps to reassemble.