RC500EX
|
3
table of contents
Copy of Safety Label ...........................................................
4
Unit Dimensions with Vertical Venting ..................................
5
Unit Dimensions with Horizontal Venting ..............................
5
Gas Line Dimensions ..........................................................
5
Manufactured Mobile Home Requirements ............................
6
Warning: Carbon Monoxide Poisoning Hazard .......................
7
MA Code - CO Detector .......................................................
8
Installation Precautions .....................................................
25
Safety Precautions for the Installer ....................................
25
Vent Restrictor Position .....................................................
25
Reversible Flue Collar .......................................................
25
Exterior Vent Terminal Locations ........................................
26
Clearances to Combustibles ...............................................
27
Locating your Gas Stove ...................................................
27
Manufactured Mobile Home Additional Requirements ..........
27
Combustion and Ventilation Air ..........................................
27
Flue Pipe Clearances to Combustibles ................................
27
Accent Light Bulb Install ...................................................
27
4” x 6-5/8” Rigid Pipe Cross Reference Chart ......................
28
Rigid Pipe Venting Systems ...............................................30
Venting Arrangements - Vertical Venting ............................31
Venting Arrangements - Horizontal Venting ........................32
Co-linear 3" - 3" Flex Pipe Venting ....................................35
Vertical Termination with Co-linear Flex System ..................36
DV Stove Horizontal Vent Kit .............................................37
DV Stove Horizontal Vent Kit Installation ............................37
Residential and Manufactured Homes / Mobile Homes
Minimum Horizontal Termination Installations .....................39
Dura-Vent Termination Kit .................................................
40
Horizontal Terminations ....................................................
41
Vertical Terminations ........................................................
42
Converting Class A Metal Chimney to Direct Vent System ....
44
Cathedral Ceilings
.............................................................45
High Elevation ..................................................................
45
Gas Connection ................................................................
45
System Data ....................................................................
45
Aeration Adjustment .........................................................
46
Gas Pipe Pressure Testing .................................................
46
Dexen Valve Description ...................................................
46
Opening the Front Glass Door ...........................................
47
Lower Access Panel Removal / Installation .........................
47
Front Grill Removal / Installation .......................................
48
Burner Removal / Installation ............................................
48
Enamel Panel Installation ..................................................
49
Conversion Kit from NG to LP ............................................
50
Log Set Installation ..........................................................
52
Optional Media Installation ................................................
55
Optional Wall Thermostat
..................................................56
Operating Using an Optional Wall Thermostat ....................
56
Remote Control Wall Mount Holder/Cradle ..........................
56
Final Check ......................................................................
56
Wiring Diagram With Optional Wall Thermostat ..................
57
Copy of the Lighting Plate Instructions ...............................
58
Normal Operating Sounds of Gas Appliances ......................
59
Maintenance Instructions ..................................................
59
Flame Pattern ..................................................................
59
Glass Gasket ....................................................................
60
Glass Replacement ...........................................................
60
Valve Assembly Replacement ............................................
60
Vent Reassembly/Replacement ..........................................
60
Accent Light Bulb Replacement .........................................
60
Gas Maintenance ..............................................................
61
Troubleshooting ...............................................................
62
Main Assembly .................................................................63
Accessories ......................................................................
66
Warranty ....................................................................68
Gas Installation Checklist ....................................................
9
Remote/Receiver Pairing ...................................................
11
Lighting Procedure ...........................................................
12
Shutdown Procedure ........................................................
12
Important Message ........................................................13
Specifications ...................................................................13
Information for Mobile / Manufactured Homes ...................13
Before You Start ...............................................................13
Copy of the Lighting Plate Instructions ...............................
14
Remote Control Operating Instructions .............................
15
First Fire ..........................................................................
19
Operating Instructions ......................................................
19
Backup Battery
.................................................................19
Opening the Front Glass Door ...........................................
20
Manual Operation (No Remote) .........................................
20
Safety Screen Installation / Removal .................................
21
Levelling Leg Adjustment ..................................................
21
General Vent Maintenance ................................................
22
Log Replacement .............................................................
22
Glass Replacement ...........................................................
22
Outside Side Glass Replacement ........................................23
Accent Light Bulb Replacement .........................................23
Fan Maintenance / Replacement ........................................23
Warranty ....................................................................68
General Safety Information ...............................................
24
Installation Checklist .........................................................
24
Venting Introduction .........................................................
25
Owner's Information
Installer's Information
On Demand Pilot (Seven Day Safety Timer)
Important information if using the appliance in CPI (continuous pilot
mode) only
This appliance is a Dexen control system fitted with the “On Demand” Pilot, a safety
feature which will shut down the gas valve completely by extinguishing the pilot
light in the event of a continuous full seven days of inactivity.
This only applies if the CPI (continuous pilot) switch is in the “on” position in your
remote control transmitter.
Each time the main burner shuts down, manually or through the call from the
thermostat, the seven day timer starts again.
The seven day inactivity timer is controlled within the circuit board. Therefore,
if in CPI mode and when the pilot light is extinguished after seven straight days
of inactivity, the CPI setting on the remote control transmitter will remain in the
“CPI” (continuous pilot) position. Therefore, all that is required to relight the pilot
would be to press the power button on the remote control transmitter from “on”
to “off” and back to “on”. Once the pilot has re-established operation will resume
as normal. There is no requirement to do anything with the IPI/CPI mode on the
remote control transmitter.
If the unit never goes as long as seven full days without a call for heat, the pilot
will remain lit until it is manually shut-off.
If the unit is being operated in IPI (intermittent pilot) mode, neither the above
instructions nor the seven day timer will apply.
See the instructions in this manual and on the Lighting Instructions plate on the
appliance to light or re-light the pilot.
Summary of Contents for Contura RC500EX
Page 67: ...RC500EX 67 notes ...
Page 72: ...72 RC500EX warranty ...
Page 73: ...RC500EX 73 notes ...
Page 74: ...74 RC500EX notes ...