32
|
City Series CB40E-12
installation
Optional Flush Chase Vent Installation - Part #657-991 (White)
Max
3
”
(76 mm)
Ceiling
Ceiling
Top of chase enclosure
Max
3
”
(76 mm)
Stud
Stud
Stud
Stud
40”
(1016 mm)
Chase Vent
C40 Chase Vent Framing Clearances
Opening for vent
4”-4.5”
(102 mm x 114 mm)
Min 42.25”
(1073 mm)
Framed
o
pening must be between 4”
(102 mm)
and 4.5”
(114 mm)
tall, and at least 42.25”
(1073 mm)
wide
to acco
m
modate the
c
hase vent.
The top of the chase vent opening must be
3
” or less from the top of the
chase enclosure.
40”
(1016 mm)
Chase Vent