City Series CB40E-12
| 81
installation
919-674
06.09.16
CB40E INNER PANELS
1. Install inner lower base panel.
2. Install panel clips into the slots at the top of the panel as shown.
3. Manoeuvre in back panel to the back wall of the unit—secure in place
with 2 panel clips and 2 screws.
CB40E OUTER PANELS
Outer side panel install
Outer base panel install
Note: Install inner safety glass prior to installation of outer panels-see
instructions in manual
1. Attach Regency logo to the right hand side of outer front panel. The
magnets will be positioned under the outer front base panel to secure
the logo. The logo should be about 3 inches from the right hand corner
of the outer base. Install outer front base panel.
2. Install side panel - the side panel is secured in place by existing
magnets in the unit.
The CB40E can be equipped with optional steel inner panels.
CB40E - 3 outer panels and 2 inner panels.
Turn off unit and allow to cool to room temperature. Remove the safety
glass and firebox glass — see manual for instructions
3. Install outer safety glass.
4. Reverse steps to remove panels.
4. Reverse steps to remove panels.
Panel Clips
Location of
Regency Logo
Part # 656-114/each
1
CITY SERIES
Inner Panels - CB40E
Outer Panels - CB40E
CB40E Painted Panel Installation (Part # 656-917)