30
|
City Series CB40E-12
installation
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may
NOT
be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are
not adhered to. It is of greatest importance that this fireplace
and vent system be installed only in accordance with these
instructions.
Clearances
Clearance: 3 sided
Dimension
Measured From:
A: From Floor
Min. 0"
Bottom of Fireplace Opening
A1 : Mantel Height (min.)
**
Top of Fireplace Opening
B: Sidewall (on one side)
8-1/2" (216mm)
Side of Fireplace Opening
C: Enclosure Width (min.)
48-7/16" (1230mm)
Minimum inside dimensions
D: Mantel Depth (max.)
**
E: Alcove Width
84" (2134mm)
Side wall to side wall (min.)
F: Alcove Depth
36" (914mm)
Front of Unit
G: To Enclosure Ceiling (min/max)
0-3" (0-76mm)
From top of enclosure
H: Convection Air outlet
120 sq. inches (min)
* Top/front or side of enclosure
I: Enclosure Depth (min.)
19" (483mm)
Minimum inside dimensions
J: Opening Height
15-1/16" (383mm)
Bottom/Top of Fireplace Opening
K: To Ceiling (min) All 3 sides
1-1/2" (38mm)
To Top of Ceiling
L: Chase Enclosure (min.)
63" (1600mm)
From base of unit/floor
M: Clearance to sprinkler head
(Min.)
36" (914mm)
Perpendicular from chase grill
Hearth
0"
No hearth required
**
See mantel clearances chart in this manual
Flue Clearances to Combustibles
Horizontal - Top
3" (76mm)
Horizontal - Side
2" (51mm)
Horizontal - Bottom
2" (51mm)
Vertical
2" (51mm)
Passing through wall/
floor/ceiling - when
firestop is used.
1-1/2" (38mm)
* A minimum of 120 square inches of open area, not lower than 3" (76 mm) from top of
enclosure, required for all installations — this can be achieved by having an open area in
front, each side, and/or above as shown in the four diagrams on the next page.
The
HeatWave
Duct Kit has
different clearance and framing re
-
quirements, check the
HeatWave
manual for details.
E
F
Alcove
Side view
L
Chase grill
Sprinkler
M
Summary of Contents for CB40E-LP12
Page 106: ...106 City Series CB40E 12 warranty ...
Page 107: ......