30
|
Regency
®
PG36 Gas Fireplace
operating instructions
Normal Operating Sounds of
Gas Appliances
It is possible that you will hear some sounds from
your gas appliance. This is perfectly normal due to
the fact that there are various gauges and types
of steel used within your appliance. Listed below
are some examples. All are
normal operating
sounds
and should not be considered as defects
in your appliance.
Blower:
Regency
®
gas appliances use high tech blowers
to push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of your
fan speed control.
Burner Tray:
The burner tray is positioned directly under the
burner tube(s) and logs and is made of a different
gauge material from the rest of the firebox and
body. Therefore, the varying thicknesses of steel will
expand and contract at slightly different rates which
can cause "ticking" and "cracking" sounds. You
should also be aware that as there are temperature
changes within the unit these sounds will likely
re-occur. Again, this is normal for steel fireboxes.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will expand
and contract at different rates resulting in some
"cracking" and "ticking" sounds will be heard
throughout the cycling process.
Adjusting Flame Height
There are six flame settings that can be adjusted
by pressing and releasing the plus (+) and minus
(-) FLAME button.
The FLAME setting button is located on the control
panel in behind the pedestal door.
Summary of Controls
On/Off Button
If the unit is switched off, pressing and releasing
this button once will switch the unit on. The unit will
resume its last settings.
If the unit is switched on, pressing and releasing
this button once will switch the unit off.
Flame:
Increase -
If the unit is switched on, pressing and
releasing the plus (+) button once will increase
the flame height to the next available high setting.
Decrease -
If the unit is switched on, pressing and
releasing the minus (-) button once will decrease
the flame height to the next available low setting.
Fan:
The fan speed is changed by pressing and releasing
the fan button.
It operates in 4 modes: OFF, LOW, MEDIUM and
HIGH.
WARNING:
DO NOT PLACE ARTICLES ON OR AGAINST THIS
APPLIANCE.
WARNING:
DO NOT USE OR STORE FLAMMABLE MATERIALS
IN OR NEAR THIS APPLIANCE
WARNING:
DO NOT MODIFY THIS APPLIANCE.
WARNING:
DO NOT SPRAY AEROSOLS IN THE VICINITY OF
THIS APPLIANCE WHILE IN OPERATION.
Note: If you have an incorrect flame
pattern, contact your Regency
®
dealer for further instructions.
Incorrect flame pattern will have small, probably
yellow flames, not coming into proper contact
with the rear burner or flame sensor.
Burner
Flame Sensor
Pilot
Ignitor
Pilot Adjustment
Periodically check the pilot flames. Correct flame
pattern has two strong blue flames: 1 flowing around
the flame sensor and 1 flowing across the burner (it
does not have to be touching the burner).