PG36 Gas Fireplace
installation
Flueing
Regency
®
Direct Vent System (Flex)
Horizontal Terminations Only
These flueing systems, in combination with the PG36 Room Sealed Gas Fireplace, have been tested and listed as a Direct Vent type flue system by the
Australian Gas Association. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in the "Exterior
Flue Termination Locations" section.
Regency
®
Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the PG36 with a maximum run of 1200 mm.
1)
175 mm dia. flexible liner (1200mm length)
2)
102 mm dia. flexible liner (1200mm length)
3)
spring spacers (4)
4)
thimble
5)
AstroCap
termination cap (1)
6)
screws (12)
7)
tube of Mill Pac (1)
8)
plated screws (8)
9)
screws #8 x 38 mm Drill Point, Stainless
Steel (4)
If longer runs are needed, the Regency
®
Direct Vent system (Flex) # 946-516 includes
all the parts needed to install the PG36 with
a maximum 3.0m run.
1)
175 mm dia. flexible liner (3.0m length)
2)
102 mm dia. flexible liner (3.0m length)
3)
spring spacers (7)
4)
thimble
5)
AstroCap
termination cap (1)
6)
screws (12)
7)
tube of Mill Pac (1)
8)
plated screws (8)
9)
screws #8 x 38 mm Drill Point, Stainless
Steel (4)
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency
®
may be used for Flex installations.