22
|
Regency
®
PG36 Gas Fireplace
installation
Conversion From NG To Propane Kit #517-968
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION!!
1
920-209
01.09.20
PG36NG-6/PG36LP-6
1)
Shut off the gas supply and unplug the
power cord.
2)
Carefully remove the glass, logs and
lava rock.
3)
Remove burner.
4)
Remove burner orifice with a 1/2"
wrench and discard. Use a wrench to
hold on to the elbow behind the orifice.
5)
Reinstall new burner orifice stamped #52
and tighten.
6)
Pull out the pilot hood by hand.
9)
Adjust the burner aeration setting to full
open and re-install the burner.
10)
Open the bottom louver.
Conversion Kit #517-968 from NG to LPG
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER,
IF IN DOUBT DO NOT DO THIS CONVERSION !!
8)
Put in the new LPG orifice with the allen
key. Then put back the pilot hood.
Burner Orifice
Pilot
Hood
Pilot
Hood
removed
7)
Remove the pilot orifice with the allen
key.
Propane Conversion Kit Contains:
Qty. Part #
Description
1
904-390
Burner Orifice #52
1
904-529
5/32" Allen Key
1
918-590
Label "Converted to LP"
1
919-728
Orange Propane label
1
910-037
#30 ULPG Pilot Orifice
1
920-209
Instruction Sheet
11)
Remove the front cover by undoing the 2
screws.
Front Cover
12)
Stick the conversion label "This unit has
been converted to Propane" over top of
the serial number decal.
13)
Replace the black "NG" label with the
orange "Propane" label.
14)
Carefully pull out the control box from
underneath the firebox.
Note:
The control box is held in place with
velcro.
Pilot
Orifice