20
|
Regency
®
CLASSIC™ C34-11 Direct Vent Freestanding Gas Stove
|
20
installation
C34E-11
05.23.19
920-109
Caution: Ensure that the wires do not
touch any hot surfaces.
FAN REMOVAL
1.
Disconnect the power to the fan.
2.
Allow the stove to cool to room temperature.
3.
Open the pedestal door and remove the screws on the door cover plate.
(Leg units: remove the bottom access panel.)
4.
Unplug the fan from the FCM.
5.
Loosen the screws of the nutserts.
6.
Remove the fan assembly from the key slots at the fan base and pull fan
out through the rectangular opening. (Diagram 5).
7.
Turn fan 90 degrees. (Diagram 5). (Pedestal units only).
8.
Disconnect the green ground wires to the grounding lug.
9
Remove fan from stove. (Diagram 3)
IMPORTANT:
THESE FANS COLLECT A LOT OF DUST FROM WITHIN YOUR HOME.
ENSURE YOU MAINTAIN THESE FAN MOTORS ON A REGULAR BASIS
BY VACUUMING THE FAN BLADES AND THE HOUSING WITH A SOFT
BRUSH NOZZLE.
Note: The #8 ground lug is a dedicated ground for mobile home
use only.
10.
Install the FCM (fan control module) to the fl oor of the pedestal or bottom
heat shield with supplied magnets. Connect the FCM power cord to the
supplied extension cord and then run extension cord out the back of the
unit. See below.
11.
Plug the fan into the FCM.
)DQ&RQWURO0RGXOH
*URPPHW
Place supplied grommet around cord when running extension cord
through the Pedestal
Run the extension cord through the largest opening at the back when using
the Bottom Heat Shield with Legs option–no strain relief grommet required.
Diagram 8
Diagram 10