Regency
®
CLASSIC™ C34-11 Direct Vent Freestanding Gas Stove | 43
|
43
operating instructions
Incorrect flame pattern will have small,
probably yellow flames, not coming into
proper contact with the rear burner or
thermopile or thermocouple.
PILOT ADJUSTMENT
Periodically check the pilot flames. Correct flame
pattern has three strong blue flames: 1 flowing
around the thermopile, 1 around the thermocouple
and 1 flowing across the burner (it does not have
to be touching the burner).
Note: If you have an incorrect flame pattern,
contact your Regency
®
dealer for further
instructions.
Top View of pilot flame
Top View of pilot flame
AERATION ADJUSTMENT
Natural Gas 5/16"
Propane 5/8"
This adjustment is performed by the installer
and is primarily used in installations at high
elevations. Push in for a yellow flame, or pull
out for a bluer flame. The burner aeration is
factory set but may need adjusting due to either
the local gas supply or altitude.
Caution: Carbon will be produced if
air shutter is closed too much.
Note: Aeration Adjustment should only be
performed by an authorized Regency
®
Installer at the time of installation or
service.