130-01 Operations
Refraction Technology, Inc.
vi
(a) If you are at the 130 DAS:
1.
Issue a Reset command from a PDA running PFC_130 or Physically disconnect
and reconnect power to the unit.
2.
Observe the LCD for the following messages:
READING DISK DO NOT DISTURB
WRITING FLASH DO NOT DISTURB
3.
The 130 DAS resets and returns to normal messaging.
(b) If you are remotely connected to a 130 DAS via telemetry mode:
1.
If you are connecting remotely by a TCP connection:
a.
First connect
b.
Discover the unit
c.
Acquire status
2.
Issue a reset command from the Status screen.
3.
Delete the unit from the Station List screen.
4.
Wait at least 5 minutes.
5.
At the Connections screen (reconnect id using a TCP connection) issue a Station
Discovery again to discover the 130 DAS station.
Note: DO NOT DISTURB THE UNIT until the start-up LCD message reappears.