7. Apply a small amount of grease to the nut threads (4) and replace the nut on the
RDL-3000. The threaded nut (4) must be finger-tight plus 1/8th turn only -- excessive
force may damage the connector or defeat the waterproof seal.
8. Waterproof the Ethernet port (see instructions on following page).
Important
: The assembled connector must be finger-tight plus 1/8th turn only. Use the
correct tool for final tightening.
Figure 28: Procedures - Ethernet Port - Weatherproof Connector Components
Disconnecting the Ethernet Cable
The RJ-45 connector is recessed within the RDL-3000 chassis. To disconnect the
Ethernet cable from the RDL-3000, you must release the locking tab located in the
chassis recess. Carefully lift the tab to release the RJ-45 connector.
Figure 29: Procedures - Ethernet Port - Ethernet Connector Locking Tab
Ethernet Cable Removal
-
Use of excessive force when removing the Ethernet cable will damage the RJ-
45 connector and the RDL-3000 printed circuit board.
-
Do not insert any tool more than 1/2 inch into the port opening.
-
Apply only very light upward pressure to disengage the plastic tab
-
Use only a light pull (two fingers) to remove the Ethernet cable.