![Redline RDL-3000 SC Installation Manuallines Download Page 50](http://html.mh-extra.com/html/redline/rdl-3000-sc/rdl-3000-sc_installation-manuallines_1429318050.webp)
RDL-3000
INSTALLATION GUIDELINES
70-00159-01-06
Proprietary Redline Communications © 2012
Page
50
of 65
kune 12, 2012
Figure 42: Procedures -
Configuration -
Product Options Screen
5.5.4
Step 4: Required Wireless Settings
Review and adjust the following parameters as required. Refer to the site survey
information.
Table 15: Procedures - RDL-3000 Parameter Settings
Step Screen
Parameter
Ref.
Sector Controller
Subscriber
1
Utilities
->
Product
Options
Options Key
RF Plan
Enable PMP SC
mode, RF freq., etc.
Enable PMP SS
mode, RF freq., etc.
2
Configuration System Name
Net. Plan
Name for SC
Name for SS
->
System
IP Address
Net. Plan
IP address for SC
IP address for SS
3
Configuration System Mode
RF Plan
PMP SC
PMP SS
->
Wireless
Channel Width
RF Plan
Use the same setting for SC and SS.
RF Freq.
RF Plan
Use the same setting for SC and SS.
Tx Power
RF Plan
Refer to RF Plan
Refer to RF Plan
Max. Distance
RF Plan
Refer to RF Plan
N/A
Antenna Gain
1
RF Plan
See Mfg. Spec.
1
See Mfg. Spec.
1
4
Provisioning
->
Subscriber
Links
Subscriber MAC RF Plan
MAC address of
each subscriber in
the sector.
N/A
Notes: 1. DFS enabled systems only.