Advice:
Low Hot Start: for thin metal sheets
High Hot Start for metals that are difficult to weld (dirty or oxidized parts).
To set the Hot Start, follow these steps:
Press the switch (5).
«HS» (Hot Start) blinks and a number is displayed.
Set the desired percentage (display (1)) using the (4) keys.
Validate by pressing the switch (5).
TUNGSTENE ELECTRODE WELDING UNDER INERT GAS (TIG MODE)
The DC TIG welding requires a protective gas (argon)
Follow the steps as below:
-
Connect the earth clamp on the positive pole (+).
-
Connect a torch «valve» negative polarity (-).(Ref. 044425)
-
Connect the pipe gas torch on the gas cylinder
-
Select the TIG position (3) using the selector button (5) (press and hold for 3 sec).
-
Adjust the wished current (display (1)) using the keys (4).
Advice: Take 30A/mm as a default setting and adjust according to the part to
weld. 6. Set the gas flow on flewmeter of the gas cylinder, and then open the valve
of the torch.
-
To boot : Touch the electrode on the welding part
-
At end of welding: Up 2 times the arc (up-down-up-down) to trigger the
automatic fade (see paragraph below). This movement must be performed in less
than 4 sec, at a height of 5 to 10 mm. Then close the valve to stop the torch gas
after cooling of the electrode.
Automatic Arc slope with time adjustable
Function activation:
This corresponds to the end of welding time required for the gradual decline in the welding current until the stop of the
arc. This function helps to avoid cracks and craters at end of welding.
1. Press the selector switch (5)
2. Set the automatic arc slope you wish from 1 to 10 sec (display(1)) using key
3. Validate the required figure by pressing the selector button (5).
Summary of Contents for MMAX9
Page 1: ...WELDING MACHINE MMAX9 1 EN INSTRUCTION MANUAL 5 DE BEDIENUNGSANLEITUNG 12 RU 22...
Page 22: ...MMAX9 22 RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 2000 6500 10...
Page 23: ...MMAX9 23 RU 11 2 A...
Page 24: ...MMAX9 24 RU CEI 61000 3 12 EMF EMF C A B C D E F G H c 10 CISPR 11 2009...
Page 25: ...MMAX9 25 RU B C D E F 10 IP21 12 5...
Page 26: ...MMAX9 26 RU MMAX9 MMA DC MMA Tig 100 240 16A CEE7 7 230 50 60 I1eff MMAX9 265 400 50 60...
Page 28: ...MMAX9 28 RU 5 1 10 1 4 5 0 5 5 10 130 1 6 9 8 6 7 4 8 130 200 2 4 11 7 8 L 2 5 x d d L...
Page 29: ...MMAX9 29 RU 2 6 6 MMA TIG 100 240 AC TIG...
Page 32: ...MMAX9 32 12 5...