RED DSMC OPERATION GUIDE
COPYRIGHT © 2014 RED.COM, INC
955-0020_V5.2, REV-G | 99
caps are made to protect the lens, not necessarily to block light.)
‒
If possible, use a dark room.
‒
Just closing the aperture is NOT sufficient.
4. Ensure a properly formatted SSD is attached to the camera.
Even if you are not saving the calibration map to the DSMC, an SSD is required to store RAW images during
calibration.
5. Go to
Menu
>
Settings
>
Maintenance
>
Calibrate
>
Sensor
.
NOTE:
If the calibration map name is “empty”, that means that the only calibration map on your camera is
the factory calibration.
6. For EPIC DRAGON or SCARLET DRAGON, you can create up to four (4) calibration maps at a time. Select
a check box for each calibration map you want, select the exposure you want for each from the drop-down
menus, and go to
.
7. For EPIC MYSTERIUM-X or SCARLET MYSTERIUM-X, select one (1) of the following:
‒
Save As user HS
: The calibration map created by black shading will overwrite the user HS calibration
map. User HS is the name for the current in-camera user-created calibration map.
‒
Save To Media
: The calibration map created by black shading will be saved to an SSD.
‒
Leave both
Save
check boxes deselected: The calibration will only be applied until the camera turns off,
and will not be saved.
8. For EPIC MYSTERIUM-X or SCARLET MYSTERIUM-X, select the last check box. The label for the check box
is the name of the user-created calibration map you will be overwriting.
NOTE:
If the calibration map name is “empty”, that means that the only calibration map on your camera is
the factory calibration.
NOTE:
The Start Capture button is disabled until you select this check box.
9. For EPIC MYSTERIUM-X or SCARLET MYSTERIUM-X, select the exposure you want to use for the calibration
from the drop-down menu.
10. Select
Start Capture
.
11. After selecting Start Capture, a dialog box displays, reminding you to cover the sensor and insert an SSD.
Select
OK
to continue.
The system initializes and then makes two (2) passes through the following phases of the calibration:
‒
Capturing
‒
Analyzing
‒
Erasing
‒
Programming
12. When the Calibration Successful dialog displays, select
OK
to complete black shading.
The new calibration map is automatically selected.
Summary of Contents for DSMC DRAGON
Page 1: ...EPIC SCARLET V5 2 DRAGON MYSTERIUM X RED COM RED DSMC O PERAT ION GU IDE...
Page 170: ...COPYRIGHT 2014 RED COM INC RED DSMC OPERATION GUIDE 955 0020_V5 2 REV G 170 SIDE VIEW...
Page 171: ...RED DSMC OPERATION GUIDE COPYRIGHT 2014 RED COM INC 955 0020_V5 2 REV G 171 TOP VIEW...
Page 172: ...COPYRIGHT 2014 RED COM INC RED DSMC OPERATION GUIDE 955 0020_V5 2 REV G 172 BOTTOM VIEW...
Page 173: ...RED DSMC OPERATION GUIDE COPYRIGHT 2014 RED COM INC 955 0020_V5 2 REV G 173 BACK VIEW...