2
SPECIFICATIONS
1.
DISPLAY
: 6-digit, 0.3" (7.6 mm) high LCD display.
2.
POWER REQUIREMENTS
:
AC Power Versions
: 115 VAC (±10%), 50/60 Hz, 6 VA
230 VAC (±10%), 50/60 Hz, 6 VA
DC Power Versions
: 11 to 14 VDC @ 180 mA.
21.5 to 30 VDC @ 180 mA.
3.
COUNT INPUT
: Switch contact closures or NPN Open Collector output
sensors. (Current sinking type output sensors)
Count threshold levels are V
IL
= 0.5 V, V
IH
= 3.8 V.
Current Sinking
: Unit provides 10 K
:
pull-up load for sensors with current
sinking outputs. (Max. sensor current, 0.5 mA.)
4.
MAXIMUM COUNT RATE
: 50 Hz under all modes of operation.
5.
CONTROL INPUTS
: Active low (V
IL
= 0.5 V max.), internally pulled up
to 5 VDC through a 10 K
:
resistor (I
SNK
= 0.5 mA).
Remote Reset
: Response time = 10 msec. A low will reset the unit and
deactivate the output.
Program Disable
: A low inhibits the changing of the preset and timed
output, as well as testing the output in self-test.
6.
OUTPUT
:
Solid-State
: Current sinking NPN Open Collector Transistor. I
SNK
= 100 mA
max., V
OH
= 30 VDC max., V
OL
= 1 V @ 100 mA.
Relay
: Form C contacts max. rating 5 amps @ 120/240 VAC, 28 VDC
(resistive load), 1/8 H.P. @ 120 VAC (inductive load). The operate time is
5 msec. nominal and the release time is 3 msec. nominal.
Relay Life Expectancy
- 100,000 cycles at max. rating.
(As load level
decreases, life expectancy increases.)
Programmable Timed Output
: The timed output can be programmed from
0.01 sec. to 99.99 sec., ±0.1% + 10 msec. The timed output is set for 0.1
sec. at the factory.
7.
MEMORY RETENTION
: Non-volatile E
2
PROM retains all programmed
information when power is removed or interrupted
.
Power Cycles(ON/OFF)
: 100,000 min.
Data Retention
: 10 years min.
8.
INPUT, POWER, AND OUTPUT CONNECTIONS
: Removable terminal
blocks.
9.
ENVIRONMENTAL CONDITIONS
:
Operating Temperature
: 0 to 50°C
Storage Temperature
: -40 to 70°C
Operating and Storage Humidity
: 85% max. relative humidity
(non-condensing) from 0°C to 50°C.
Altitude
: Up to 2000 meters
10.
CERTIFICATIONS AND COMPLIANCES
:
SAFETY
IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
Type 4X Enclosure rating (Face only), UL50
ELECTROMAGNETIC COMPATIBILITY
Notes:
1. Power lines had an external EMI line filter (RLC #LFIL0000 or
equivalent) installed.
2. I/O cables routed in metal conduit connected to earth ground.
Refer to the EMC Installation Guidelines section of the bulletin for
additional information.
11.
CONSTRUCTION
: Black plastic front bezel with black plastic insert.
Front panel meets NEMA 4X/IP65 requirements for wash-down and dusty
environments, when properly installed. Installation Category II, Pollution
Degree 2. (Panel gasket, mounting clip, nut fasteners, and screws included
with unit.)
12.
WEIGHT
: 0.8 lbs (0.36 kg).
Immunity to EN 50082-2
Electrostatic discharge
Level 2; 4 Kv contact
EN 61000-4-2
Level 3; 8 Kv air
Level 3; 10 V/m
EN 61000-4-3
Electromagnetic RF fields
80 MHz - 1 GHz
Level 4; 2 Kv I/O
2
Level 3; 2 Kv power
1
Level 3; 10 V/rms
1
150 KHz - 80 MHz
Power mains class A
Enclosure class A
EN 55011
EN 61000-4-6
EN 61000-4-4
Fast transients (burst)
RF conducted interference
Emissions to EN 50081-2
RF interference
MODEL
DESCRIPTION
PART NUMBERS FOR AVAILABLE SUPPLY VOLTAGES
NO.
12VDC
24VDC
230VAC
115VAC
LNXCC
Lynx Contact Input Counter
LNXCC020
LNXCC030
LNXCC010
LNXCC000
*
LNXC1
Lynx Single Preset Counter
LNXC1020
LNXC1030
LNXC1010
LNXC1000
*
LNXC2
Lynx Dual Preset Counter
LNXC2020
LNXC2030
LNXC2010
LNXC2000
For more information on Pricing, Enclosures & Panel Mount Kits refer to the RLC Catalog or contact
your local RLC distributor.
ORDERING INFORMATION
*
For complete details on these versions of the Lynx counters, refer to Bulletin No. LNXC1/2.
Summary of Contents for CUB 1
Page 30: ...7 This page intentionally left blank...
Page 46: ...5...
Page 47: ...6...
Page 48: ...7...