3
After cutting opening in panel, slide the panel gasket over the rear of the
counter body to the back of the bezel. Then slide counter through the panel cut-
out. Install mounting clips on each side of counter body with mounting screws.
CUB 1
Make sure the side rails or tabs of the clips fit into the recesses in the side of
the counter body so that the
“Tang Ends”
or
“Tabs”
wedge between the panel
opening and body as the screws are tightened.
CUB 2
DIMENSIONS, INSTALLATION, & BATTERY INSERTION
DIMENSIONS “In inches (mm)”
CUB 1
The battery cover is held in place by upper and lower clasps that capture
mating lock ramps on the cover. To remove, insert thumbnail and index finger
nail in the gaps between the upper and lower clasps and the battery cover, and
deflect the clasps slightly to clear the edges of the ramps while pulling out on
the cover. To replace cover, simply push into place until both clasps snap into
engagement with lock ramps.
CAUTION: Do not deflect clasps more than necessary to clear lock ramps.
Excessive deflection can cause clasps to break off.
CUB 2
Slide battery cover to the left until the right hand lip disengages and pops
out. To reinstall cover, insert left hand lips into case first, push cover to the left
until right hand lip drops down and cover snaps back into place. Install
batteries as shown below observing proper polarity.
Note: Push battery spring clips to the left (toward connector) to completely
free the batteries when removing or installing batteries. Conductive rubber
battery contacts can be torn from their retaining pins if batteries are forced
in.
BATTERY COVER REMOVAL & BATTERY INSERTION
ELECTRICAL CONNECTIONS
There are certain considerations that shoud be observed when running the
count and control signal wires. A length of wire can act like an antenna and the
closer it is to a source of electrical noise, the more it becomes susceptible to that
noise.
There are a few rules that should be followed when running these wires.
1. Never run count or control signal wires in the same conduit or raceway with
AC power lines, conductors that feed motors, solenoids, SCR controls,
heaters, etc.
2. Signal wires within enclosures should be routed as far away as possible from
contactors, control relays, transformers, and other noisy components.
3. When shielded wire is used, connect the shield to the common of the CUB
unit, and leave the other end of the shield disconnected and insulated from
machine ground.
4. Mount the CUB in a panel that is grounded to the machine frame.
5. When using accessory devices such as LCM’s or PSM’s into the H.S. CNT.
Input, the accessory devices should be mounted near the CUB Counter.
NOTES
1. Batteries NOT supplied with counters, order separately.
2 required per unit.
2. Counters supplied with required hardware. Includes 2 mounting
clips & screws, panel gasket, 2-wire nuts & blue terminal wire.
3. Counters supplied with connector body & white, yellow, & black
wires. Kit ICA includes connector body & one each of black,
white, blue, & yellow terminal wires.
MODEL NO.
DESCRIPTION
PART NUMBERS
CUB 1
CUB 1 Miniature Electronic Counter
CUB10000
CUB 2
CUB 2 Gen. Purpose Industrial Electronic Counter
CUB20000
BNA
“N” Type Alkaline Batteries (Note 1)
BNA00000
HWK 1
CUB 1 Spare Hardware Kit (Note 2)
HWK10000
HWK 2
CUB 2 Spare Hardware Kit (Note 2)
HWK20000
ICA
Spare Input Connector & Terminal Wires (Note 3)
ICA00000
For more information on Pricing, Enclosures & Panel Mount Kits refer to the RLC Catalog or
contact your local RLC distributor.
ORDERING INFORMATION