INSTALLATION ENVIRONMENT
The unit should be installed in a location that does not exceed the
maximum operating temperature and provides good air circulation.
Placing the unit near devices that generate excessive heat should be
avoided.
The bezel should be cleaned only with a soft cloth and neutral soap
product. Do NOT use solvents.
Continuous exposure to direct sunlight may accelerate the aging
process of the bezel.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to
operate the keypad of the unit.
INSTALLATION
PBLT installation information is contained in the LDD bulletin. Refer
to that bulletin for instructions on installing the module.
The unit meets NEMA 4/IP65 requirements for indoor use, when
properly installled. The units are intended to be mounted into an enclosed
panel with a gasket to provide a water-tight seal. Two mounting clips and
screws are provided for easy installation. Consideration should be given
to the thickness of the panel. A panel which is too thin may distort and not
provide a water-tight seal.
(Recommended minimum panel thickness is
1/8” {3.2 mm}.)
After the panel cut-out has been completed and deburred, carefully
slide the panel gasket over the rear of the unit to the back of the bezel.
Insert the unit into the panel.
As depicted in the drawing, install the screws into the narrow end of the
mounting clips. Thread the screws into the clips until the pointed end just
protrudes through the other side.
Install each of the mounting clips by
inserting the wide lip of the clips into the
wide end of the hole, located on either
side of the case. Then snap the clip onto
the case.
Tighten the screws evenly to apply
uniform compression, thus providing a
water-tight seal.
CAUTION:
Only minimum pressure is
required to seal panel. Do
NOT
overtighten screws.
LENGTH MEASUREMENT SYSTEM
The web system, shown in the drawing above, accumulates the total
length of paper wound onto a roll. An LSC length sensor feeds 10 pulses
into the totalizer for every foot of paper wound onto the roll. Therefore,
the Apollo Totalizer is set up to display a decimal point in the tenth’s
position so the unit will directly display in tenth’s of feet. The unit has the
front panel reset disabled so reset can only occur through the remote reset
terminal. The
“STORE”
terminal is connected through a push button to
common. This allows the operator to
“freeze”
the display
(no counts are
lost)
so the latest reading can be recorded.
(Note: With the Apollo Totalizer
non-volatile memory, the system can be turned off at any stage winding
and the Apollo will retain, in its internal memory, the amount of paper
already wound onto the roll.)
TYPICAL APPLICATION
TROUBLESHOOTING
For further technical assistance, contact technical support at the appropriate company numbers listed.
ORDERING INFORMATION
PERSONALITY MODULE
*Requires an LDD for use.
MODEL NO.
DESCRIPTION
115 VAC
230 VAC
PART NUMBERS
APLT
Apollo 6-Digit Totalizer
APLT0610
APLT0600
Apollo 8-Digit Totalizer
APLT0810
APLT0800
For more information on Pricing, Enclosures & Panel Mount Kits, refer to the RLC Catalog or
contact your local RLC distributor.
MODEL NO.
DESCRIPTION
PART NUMBERS
PBLT*
PBLT0600
Apollo 6-Digit Totalizer Module for use
with the 4 or 6 Digit Large Digit Display
115/230 VAC