177
RESET MODE & CYCLE SWITCHES
S4 - ON:
ENABLES Front Panel Reset Button
OFF:
DISABLES Front Panel Reset
S5 - ON:
AUTO RST* - Causes counter to automatically
reset either upon reaching the preset count or
after time-out of output as determined by S6.
OFF:
MAN. - Counter will reset only in response to
Front Panel Button (if ENABLED) or Remote
Reset (R).
S6 - ON:
T.D. RST* - Causes counter to reset automatically
(with S5 ON) at end of output time delay.
OFF:
INST* - Causes counter to reset automatically
(with S5 ON) at instant preset count is reached.
S7 - ON:
LATCH - causes outputs to latch after reaching
preset. Outputs stay ON until manually reset by
Front Panel Button or Remote Reset.
OFF:
T.D. - Allows outputs to respond to normal time
delayed dropout.
S8 - ON:
LG. DLY. - Sets adjustable Time Delay Range to
0.05 - 1 sec.
OFF:
SHT. - Sets adjustable Time Delay to 0.7 - 15
msec.
*
Remote Reset (R) and Front Panel Reset (if ENABLED)
will always reset the counter regardless of automatic
setup mode used.
MODEL SCP INPUT/OUTPUT CONNECTIONS & PROGRAMMING SWITCHES
TYPICAL APPLICATION CONNECTIONS & SET-UP
A typical length-measuring wind/rewind application involving up/down
counting to accommodate forward and reverse web motion and provision for
remote reset.
RESET CYCLE MODES - SWITCHES S5, 6, 7 & 8
MODE 1 LATCH AT PRESET, MANUAL RESET
Counts from zero, activates and latches outputs ON at
preset. Front panel button (if enabled) or remote reset
(Terminal “R”) returns counter to zero and deactivates outputs.
Accepts new count pulses 75 µsec after reset is removed.
MODE 2 MOMENTARY OUTPUT AT PRESET, MANUAL RESET
Counts from zero and activates outputs momentarily at
preset. Momentary output time is adjustable from 0.05 to 1
second. Count can proceed upward if not reset, and if count
direction is then reversed, by pulling U/Ddown to B, the outputs will again
reactivate as the count decrements down through preset a second time.
Outputs activate each time the count passes through preset provided time-
out from previous pass has concluded. Front panel reset (if enabled) or
remote reset (R) returns the counter to zero and interrupts output if time-out
has not concluded. Unit is ready to accept new counts 75 µsec after removal
of reset.
MODE 3 AUTOMATIC CYCLE - RESET & RUN AT PRESET
Counts from zero, activates outputs momentarily at preset
and simultaneously resets counter to zero, ready to accept
new counts for next cycle 75 µsec after resetting. Momentary
output time is adjustable from 0.05 to 1sec. Output ON-time must be less
than time required to count from zero to reset for proper Mode 3 operation.
MODE 4 AUTO. CYCLE - RESET & RUN AFTER TIME-OUT
Counts from zero, activates outputs momentarily at preset.
Counter resets to zero at conclusion of output time-out and is
ready to accept new counts for the next cycle 75 µsec after
reset.
MODE 5 AUTO. CYCLE - PRESCALE DIVIDER
Identical to Mode 3 except momentary output time delay
range switched to “short” range (0.7 to 15 msec) by placing
S8 in OFF position. The shorter time-out allows the SCP to be
used as a pre-scaling divider providing output pulses in excess of 1 KHz to
the input of another counter.
MODEL NO.
DESCRIPTION
NO. OF
PART NO.’S FOR
DIGITS
AVAILABLE SUPPLY VOLTAGES
230 VAC
115 VAC
SCP
SC Series Preset
2
SCP00210
SCP00200
Cntr w\o Display
4
SCP00410
SCP00400
6
SCP00610
SCP00600
For more information on Pricing, Enclosures & Panel Mount Kits, refer to the
RLC Catalog or contact your local RLC distributor.
ORDERING INFORMATION