BACKLIGHT OPTION (CUB7 SERIES)
Optional backlight versions of the CUB7 series require an external 9-28
VDC power supply. The external supply is connected between V+ and
Common terminals as shown by the solid line in the drawing.
RESET OPTIONS (CUB7 SERIES)
Connecting a wire from the RST. EN. (Reset Enable) Input terminal to
Common will enable the front panel Reset button.
Pulling the “RST.” input low causes the counter to reset. The “RST.” can
be pulled low by either a mechanical switch or solid-state transistor switch.
Switch load is 15 µA (max. voltage drop 0.5 V) when on. The off-state
leakage current must be less than 2 µA
Note: The RC protection circuit on the “RST.” Input causes a delay of
approximately 15 msec in Reset response.
BATTERY INSTALLATION
1. Remove all power to the unit before removing battery cover.
2. To remove battery cover, push upward in the direction of the arrow on rear
cover (See drawing at right), until the cover unlatches. Pull cover straight
out from unit to fully remove.
3. Remove old battery* and replace with an RLC battery (BNL10000).
Observe proper polarity when replacing battery as shown in drawing.
4. Replace cover. The battery cover is keyed so that it cannot be placed upside
down. The arrow on the rear of the cover should point toward the top of the
CUB7 series when properly installed
* - Dispose of properly.
WARNING
: Lithium battery may explode if incinerated.
TROUBLESHOOTING
For further technical assistance, contact technical support at the appropriate
company numbers listed.
Red Lion Controls
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
Red Lion Controls AP
31, Kaki Bukit Road 3,
#06-04/05 TechLink
Singapore 417818
Tel +65 6744-6613
Fax +65 6743-3360
Red Lion Controls BV
Basicweg 11b
NL - 3821 BR Amersfoort
Tel +31 (0) 334 723 225
Fax +31 (0) 334 893 793
LIMITED WARRANTY
The Company warrants the products it manufactures against defects in materials and workmanship
for a period limited to two years from the date of shipment, provided the products have been stored,
handled, installed, and used under proper conditions. The Company’s liability under this limited
warranty shall extend only to the repair or replacement of a defective product, at The Company’s
option. The Company disclaims all liability for any affirmation, promise or representation with
respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against
damages, claims, and expenses arising out of subsequent sales of RLC products or products
containing components manufactured by RLC and based upon personal injuries, deaths, property
damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be
to any extent liable, including without limitation penalties imposed by the Consumer Product Safety
Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty
Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those
expressly contained herein. The Customer acknowledges the disclaimers and limitations contained
herein and relies on no other warranties or affirmations.
Summary of Contents for CUB 1
Page 30: ...7 This page intentionally left blank...
Page 46: ...5...
Page 47: ...6...
Page 48: ...7...