Parameter explanations V2.1_V2.6
2
IRA_B8_EN_2V2_REC_102-020401137
22/ 56
→ OP door 2
Button-operated door for the hermetic closing of an operating
room.
▪ Default parameters:
Parameter
Default value
Driving cycle → Ramp → Sec-
tion
20
Driving cycle → Seal
20
For more parameters, see OP
door 1
→ Folding door, Basic
escape route
This door type is a combination of
Basic escape route
and
Folding door
door types (see above).
→ Industry 1
For protection doors on machine tools from Bühler AG, Uzwil.
▪
Dead man
-control with a signal for the opening and one for
the closing of the door.
▪
Automatic
or
Manual
operating modes can be set via
BDE-M.
▪ No collision detection 35 mm before end points.
▪ After a collision in the closing action the door reverses
direction as long as the closing command is activated. Af-
terwards, the alarm relay is activated for 2 seconds.
▪ After a collision in the opening action the door stops. Af-
terwards, the alarm relay is activated for 2 seconds.
▪ If the door is not calibrated (no running parameters) this is
displayed on the output which is normally planned for con-
necting a brake.
▪ Default parameters:
Parameter
Default value
Driving cycle → Seal
40
Control panel → BDE-M
3 positions (AUTO)
Control panel → Default op.
mode
Automatic
Input/Output → STG →
AUX0_IN
BDE-M_2
Input/Output → STG →
AUX0_IN
OPEN DEAD MAN
Input/Output → STG →
AUX4_IN
CLOS. DEAD MAN
Summary of Contents for system 20
Page 1: ...record system 20 B8 Parameter explanations Translation of the original manual ...
Page 48: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 48 56 ...
Page 50: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 50 56 ...
Page 52: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 52 56 ...
Page 54: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 54 56 ...
Page 56: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 56 56 ...