Parameter explanations V2.1_V2.6
2
IRA_B8_EN_2V2_REC_102-020401137
40/ 56
→ AKI / AKA
This output signal indicates that a triggering signal on the inner
or outer side of the door is active.
▪ The output connects independently of the current operating
mode.
→ SSK
This output signal shows that an SSK signal is active.
▪ The output connects independently of the current operating
mode
→ SAMP
Signal for connecting an optical and/or acoustic indicator in an
interlock control.
▪ This signal shows that an opening command is registered,
but cannot yet be carried out, because the interlock is oc-
cupied from the opposite door.
→ SAA
Output signal for synchronisation of an interlock.
▪ With the signal
Block triggering
the other door is notified
that the interlock is currently occupied.
→ SFS_OUT
Output interlock sequential control.
▪ Appropriate for interlocks and draught lobbies without trig-
gering sensors within the interlock chamber.
▪ The signal must be linked with the input signal SFS_IN of
the other door. Thus, the triggering signal is transmitted to
the first door.
→ APS signal light
For connecting a signal light in a pharmacy control.
▪ The signal shows that the pharmacy function is activated
and the door can be opened with the
APS opening
signal.
▪ It is recommended to use an opening switch with integrat-
ed lighting and to connect the output to the lighting.
→ Automatic OM
The relay is active as long as
Automatic
operating mode is
selected - also in the event of reduced opening width.
→ One-Way OM
The relay is active as long as
One-Way
operating mode is
selected - also in the event of reduced opening width.
→ Locked OM
The relay is active as long as
Locked
or
Locked manual
oper-
ating mode is selected.
▪ The signal remains active even during an SSK opening.
→ Continuously open OM
The relay is active as long as
Continuously open
operating
mode is selected - also in the event of reduced opening width.
→ Manual OM
The relay is active as long as
Manual
operating mode is se-
lected.
→ Off OM
The relay is active as long as
Off
operating mode is selected.
Summary of Contents for system 20
Page 1: ...record system 20 B8 Parameter explanations Translation of the original manual ...
Page 48: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 48 56 ...
Page 50: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 50 56 ...
Page 52: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 52 56 ...
Page 54: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 54 56 ...
Page 56: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 56 56 ...