Parameter explanations V2.1_V2.6
2
IRA_B8_EN_2V2_REC_102-020401137
10/ 56
→ Reduced opening width
(with RED)
40 With RED doors, this parameter helps configure the Escape
route width. This is normally specified by each country’s build-
ing inspection and can also be shared for several doors.
0 = minimum opening width
40 = total opening width
▪ The escape route opening width can only be set with the
service unit FPC902.
▪ It is not allowed to fall below an opening width of 40 cm per
door leaf.
▪ Door openings in escape route direction (AKI) are time
monitored. With doors up to 2 m opening width, 80% of the
adjusted opening width of the escape route must be
reached within 3 seconds. In case of wider doors, the time
allowed is accordingly longer.
→ Collision CLOSE
20 Reaction point for a collision detection during closing run (main
closing edge)
0 = smooth
40 = rough
▪ The kinetic energy of the moving door is partially absorbed
by the controller to notice the increased expenditure of
force.
Collision OPEN
20 Reaction point for a collision detection during opening run
(secondary closing edge).
0 = smooth
40 = rough
▪ The kinetic energy for the moving door is partially ab-
sorbed by the obstacle. According to its characteristics, it
takes a certain time for the controller to notice the in-
creased expenditure of force.
Brake
This parameter determines in which stop positions and in
which operating modes the motor brake should be actuated.
▪ After safety openings (SÖK; EMERGENCY OPENING,
ect.) the brake is generally not actuated. For this reason,
the door can still be totally opened by hand or with the rub-
ber cord (CO48).
Without
X No brake.
Closed position
The brake is applied in all operating modes when in the closed
position.
Summary of Contents for system 20
Page 1: ...record system 20 B8 Parameter explanations Translation of the original manual ...
Page 48: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 48 56 ...
Page 50: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 50 56 ...
Page 52: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 52 56 ...
Page 54: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 54 56 ...
Page 56: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 56 56 ...