Parameter explanations V2.1_V2.6
2
IRA_B8_EN_2V2_REC_102-020401137
24/ 56
→ Analogue BDE-A
Mechanical BDE for USA.
BDEM_1
Opening width
0V
Complete opening width
24V
Reduced opening width
BDEM_2
Operating mode
approx. 2.5V
OFF
approx. 7.5V
Continuously open
approx. 13V
One-Way
approx. 19V
Automatic
→ Standard Reduced
BDEM_2
BDEM_1
Oper. mode
Open. width
0V
0V
Locked
Unchanged
0V
24V
Cont. open
Unchanged
24V
0V
Automatic
Total
24V
24V
Automatic
Reduced
→ Analogue Reduced
BDEM_2
Operating mode
Opening width
approx. 2.5V
Locked
Unchanged
approx. 7.5V
Continuously open Unchanged
approx. 13V
Automatic
Reduced
approx. 19V
Automatic
Total
→ BDE-D
Settings for control unit with display.
▪ All parameters for the BDE-D are saved in the STM. Some
parameter changes are only overtaken by the BDE-D after
a restart of the controller.
→ Language
Range of languages for text displays on the BDE-D.
Currently, the following languages are available: DEUTSCH,
FRANÇAIS, ENGLISH, ENGLISH US, ITALIANO, ESPAÑOL,
NEDERLANDS, DANISH, SLOVENSCINA, POLSKI, MAG-
YAR and CZECH.
▪ Older BDE-D hardware offers a limited range of languages
due to its reduced memory.
→ Keyboard
Layout and function of the keys.
→ Normal
X Standard layout
→ OFF-Mode
Layout for the USA. The Locked key activates the operating
mode
OFF
instead of mode
Locked
. The door goes into
Man-
ual
mode and can then be locked manually.
Summary of Contents for system 20
Page 1: ...record system 20 B8 Parameter explanations Translation of the original manual ...
Page 48: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 48 56 ...
Page 50: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 50 56 ...
Page 52: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 52 56 ...
Page 54: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 54 56 ...
Page 56: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 56 56 ...