Parameter explanations V2.1_V2.6
2
IRA_B8_EN_2V2_REC_102-020401137
11/ 56
Open position
If the door has reached the planned opening width, pull the
brake in all operating modes. This is also valid in case of re-
duced opening width.
▪ If the door stops e.g. due to safety signals or because of a
collision, the brake is not activated.
Closed/Open position
In all operating modes pull the brake when the door is closed
or open (see above).
Closed, One-Way/Locked
In operating modes
One-Way
and
Locked
pull the brake when
the door is closed.
Closed, Locked
Only pull the brake in operating mode
Locked
when the door is
closed.
Motor
Definition of the motor type (ATE) being used.
▪ If no motor type is yet configured (e.g. according to factory
settings), some motor types can be automatically identified
and configured by the controller software.
▪ The selection of motor types is limited according to STM
variants.
Without
X No motor is connected or motor type unknown.
ATE 20
ATE STA 20 (GR63x55), automatic identification
ATE 21
ATE STA 21 (GR63x25), automatic identification
ATE 19 small
ATE STA 19 (GR63x25), no automatic identification
ATE 19 big
ATE 19 (GR63x55), no automatic identification
ATE 16 normal
ATE 16, no automatic identification
ATE 16 heavy
ATE 16, (1:15) no automatic identification
ATE 17
ATE 17 (GR63x25), no automatic identification
ATE 20 folding door
ATE 20 with special pulley for,
folding door type
automatic
identification in case of a folding door.
ATE 16 folding door
ATE 16 with special pulley for
folding door
no automatic identi-
fication
ATE 16 30V
ATE 16 30V for industrial application, no automatic identifica-
tion.
ATE 20/200
ATE 20/200 (GR63x55) with special pulley for 200 mm installa-
tion height, no automatic identification.
Summary of Contents for system 20
Page 1: ...record system 20 B8 Parameter explanations Translation of the original manual ...
Page 48: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 48 56 ...
Page 50: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 50 56 ...
Page 52: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 52 56 ...
Page 54: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 54 56 ...
Page 56: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 56 56 ...