Parameter explanations V2.1_V2.6
2
IRA_B8_EN_2V2_REC_102-020401137
28/ 56
INPUT/OUTPUT → STG
→ BDE_V1
(only STM20/22 DUO)
→ BDE_V2
(only STM20/22 DUO)
(0V) in safety-relevant signals (e.g. SIS) means that the
signal has triggered.
▪ Normally, signals for connecting buttons only react to the
signal change over (0V 24V). Thus, for example, the door
can be opened with the AKI button, but will automatically
shut at the end of the hold-open time, even though the but-
ton is still being pressed.
→ Disabled
X
→ SÖK/NSK
(only AUX0_IN
and AUX1_IN)
Safety opening or emergency closing.
0V/open = carry out safety opening or emergency closing
24V = back to previous operating mode
▪ Requested function must be configured with
Parameter →
Input/Output → SÖK/NSK → Function
.
▪ Signal normally has highest priority. An exception is e.g.
active
Pharmacy control
.
▪ Safety sensors and reverse automatic system are not ac-
tive while closing or opening.
→ SURV
Selection of operating mode
Locked
with clock timer.
0V/open = operating mode
Locked
24V = back to previous operating mode
▪ Signal has highest priority, i.e. operating mode
Locked
cannot be exited with BDE-D.
▪ SSK and safety sensors are active.
▪ The door closes and locks even in operating modes
Manu-
al
and
Continuously open
.
→ BDEM_1
(only AUX1_IN)
Contact S1 of mechanical control unit.
▪ The type of the connected control unit must be configured
according to
Parameter → Control unit → BDE-M
.
→ BDEM_2
(only AUX0_IN)
Contact S2 of mechanical control unit.
▪ The type of the connected control unit must be configured
according to
Parameter → Control unit → BDE-M
.
→ Continuously open
Selection of operating mode
Continuously open
with pulse
button.
▪ 1st pulse (24V -> 0V/open) = operating mode
Continuously
open
2nd pulse (24V -> 0V/open) = back to previous operating
mode
▪ A locked door is unlocked, safety sensors are active while
opening.
Summary of Contents for system 20
Page 1: ...record system 20 B8 Parameter explanations Translation of the original manual ...
Page 48: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 48 56 ...
Page 50: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 50 56 ...
Page 52: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 52 56 ...
Page 54: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 54 56 ...
Page 56: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 56 56 ...