background image

MANUAL DE INSTALAÇÃO / INSTALLATION MANUAL / MANUAL DE INSTALACION

IN.21.900

LOCKING SYSTEMS

AUTOMATIC OVERHEAD DOOR CLOSER

MOLA DE PORTA AEREA AUTOMATICA

CIERRA PUERTAS AEREO AUTOMATICO 

Summary of Contents for IN.21.900

Page 1: ...MANUAL DE INSTALAÇÃO INSTALLATION MANUAL MANUAL DE INSTALACION IN 21 900 LOCKING SYSTEMS AUTOMATIC OVERHEAD DOOR CLOSER MOLA DE PORTA AEREA AUTOMATICA CIERRA PUERTAS AEREO AUTOMATICO ...

Page 2: ...WARNING IT MIGHT CAUSE DAMAGE TO THE PROPERTY OR INJURY TO THE USER UNDER THE INCORRECT USAGE IT MIGHT CAUSE A SERIES INQUIRY OR DEATH UNDER INCORRECT USAGE ...

Page 3: ... BAR 4 3 INSTALLATION OF SLIDING ARM 4 3 1 PULL BAR 4 3 2 PULL BAR FOR GLASS DOOR 4 3 3 PUSH BAR 4 3 4 PUSH BAR FOR GLASS DOOR 4 4 MECHANISM INSTALLATION 4 5 ASSEMBLE AND DISASSEMBLE OF THE MECHANISM UP COVER 5 WIRED DIAGRAM 5 1 TERMINAL DETAILS 5 2 INTERLOCK 5 3 24G MICROWAVE SENSOR IN 15 731 5 4 DIFFERENT SENSOR EXAMPLE 5 5 DIFFERENT SENSOR EXAMPLE IN 15 730 5 6 MAGNETIC LOCK 5 7 ANTI CLAMP SENS...

Page 4: ...her indications placed in origin on the automatic door operator or its accessories E Standing within the course of the door leaf of the automatic door or performing tasks near possible parts in motion 1 4 WARRANTY The manufacturer s warranty for the IN 21 900 will be VOID if A The installation use and or maintenance of the product did not follow the norms instructions and indications described in ...

Page 5: ... I Voltage AC220V 110V Input 220V AC Output 24 DC J Open device wireless push button remote control K 2000000 service life test super reliable L 55w high speed dc brushless motor long service life low noise M Control chip reliable performance digital display design mechanism is easy to adjust and fine adjust is allowed N In main and slave mode Sequence will not change because of encounter an obsta...

Page 6: ...VOLTAGE 24V DC 10 3A OPEN DEGREE Max 115º OPEN SPEED 45º s CLOSE SPEED 45º s OPENING TIME 0 60 s adjustable PROTECTION CLASS IP21 3 TECHNICAL DATA 515 80 153 80 28 5 115 500 230 230 20 6 39 5 EN NOTES Data recorded under zero wind pressure Door leaf over weight is not allowed service life will get shorter 3 3 DIMENSIONS 3 2 TECHNICAL DATA ...

Page 7: ...LESS PUSH BUTTON IN 15 732 SLIDING ARM FOR GLASS IN 21 902 C STANDARD ARM IN 21 902 B SLIDING ARM IN 21 902 A GLASS CLAMP FOR PUSH ARM IN 21 903 TOUCH SWITCH IN 24 207 E LOCK IN 28 501 NUMERIC KEYBOARD IN 28 108 NUMERIC KEYBOARD IN 28 109 TOUCHLESS SWITCH IN 21 910 DOUBLE ACTION SENSOR IN 15 730 WIRELESS TOUCHLESS SWITCH IN 21 910 WL WIRELESS RECEIVER OPTIONAL NOT NEEDED FOR THIS SYSTEM IN 21 910 ...

Page 8: ...1 www jnf pt 8 72 3 TECHNICAL DATA Power switch 0 Power off I Power on 3 6 MECHANISM COMPONENTS Leſt side cover Motor Transformer 220V input Pull bar Controller Right side cover BOTTOM PLATE PULL BAR COVER PULL GUIDER MECHANISM EN ...

Page 9: ...MI0315 1 www jnf pt 9 72 4 MECHANICAL INSTALLATION EN 4 1 BAR TYPE 4 1 1 PULL BAR OPEN TO INSIDE MECHANISM INSIDE Open direction Open direction 4 1 2 PUSH BAR OPEN TO OUTSIDE MECHANISM INSIDE Open direction Open direction ...

Page 10: ...Power cable Ø17 Power cable Ø17 Controller cable Ø17 Controller cable Right side installation Leſt side installation 31 150 133 150 31 52 35 495 495 Fix the bottom plate on the door frame with 6 screws Steel material M6 x 15 mm Inner hexagonal screw Fix the bottom plate on the door frame with 6 screws Steel material M6 x 15 mm Inner hexagonal screw 1 2 ...

Page 11: ...exagonal screw Right side installation Mechanism position Open direction Ø17 Power cable Ø17 Controller cable 31 150 133 150 31 52 495 Fix the bottom plate on to door frame with 8 screws Steel material M6 15 Inner hexagonal screw Leſt side installation Mechanism position Open direction Tip For push bar installation the mechanism and open direction are the same For pull bar installation the mechanis...

Page 12: ...e pull bar works smoothly Adjustment is requested if a resistance durig the operating 7 Fix the last screw Door leaf 1 Open the door to a 90º angle Slide the pull guide roller into the track 2 Fix the pull bar plate as shown 3 Move the plate to ensure the wheel is at the middle position of the track as shown 4 Hold the plate position and fix the first screw near the center of the shaft 5 Close the...

Page 13: ...leaf Push bar L 250mm 115 103 5 52 20 250 18 50 450 4 3 3 PUSH BAR Automatic door right installation Adjust the push bar lenght by two screw according to the door frame s depth L The glass clamp of the push arm shall be fastened on the door wing with 4 plug screws M6 12 as shown in the figure Mechanism Wall Door leaf Push bar L 250mm 115 103 5 52 20 250 18 50 450 Automatic door right installation ...

Page 14: ... plug screws M6 12 as shown in the figure 18 50 450 Tip The glass clamp of the push arm shall be fastened on the door wing with 4 plug screws M6 12 as shown in the figure 18 50 450 Note make sure there is a 10mm gap between the top of the glass and the bottom of the door when using the push arm of the glass door NOTE Make sure there is a 10mm gap between the top of the glass and the bottom of the ...

Page 15: ...ush bar with 2 screw M5 8 on glass clamp 104 52 20 115 81 200 Mechanism Open direction Wall Door leaf Glass clamp Push bar Fix the glass clamp and spacer with 4 screw M6 12 tightly on glass door Install the fix plate of the push bar with 2 screw M5 8 on glass clamp 104 52 20 115 81 200 Fix the glass clamp and spacer with 4 screws M6x12 tightly on the glass door Install the fix plate of the push ba...

Page 16: ...LLATION MANUAL MI0315 1 www jnf pt 16 72 4 MECHANICAL INSTALLATION EN Hang the mechanism on the fixed base cover with screws 4 4 MECHANISM INSTALLATION 4 5 ASSEMBLE AND DISASSEMBLE OF THE MECHANISM UP COVER ...

Page 17: ...st button is disabled on salve controller nti collision close nti collision open 24 LED will stop flash Date setting is finished lision open CONNECTION OF THE POWER SUPPLY FOR SINGLE OPEN CONNECTION OF THE POWER SUPPLY FOR DOUBLE OPEN L N EXTERNAL POWER AC100 240V 1 2 3 1 2 3 4 2 2 L N EXTERNAL POWER AC100 240V 1 24V 2 GND 3 12V 4 GND 5 OPEN A 6 COM 7 FULL LOCK 8 COM 9 OPEN B 10 COM 11 SYNCHRONOUS...

Page 18: ...R IN 15 731 DOOR A DOOR A DOOR B DOOR B 16 INTERLOCK SIGNAL IN COM 14 INTERLOCK SIGNAL OUT 13 SYNCHRONOUS IN COM 11 SYNCHRONOUS OUT 13 SYNCHRONOUS IN COM 11 SYNCHRONOUS OUT 16 INTERLOCK SIGNAL IN COM 14 INTERLOCK SIGNAL OUT TIP Er03 means synchronous cable is not well connected 13 SYNCHRONOUS IN COM 11 SYNCHRONOUS OUT Dr12 and Dr13 means that there is no bridge connection red yellow green black 1 ...

Page 19: ... collision open RED PINK BROWN WHITE RED PINK BROWN WHITE 23 Anti collision close Electronic lock Tip Magnetic lock should connect with power access Lock current lower than 800mA ALARM 9 OPEN B 3 12V 4 GND 10 COM 0 black 12V red 18 GND 17 COM NC NO OPEN GND 12V D IN D1 D0 22 GND 22 GND 20 24V NO COM GND 24V Anti clamp sensor when opening 24 Anti collision open RED PINK BROWN WHITE Electronic lock ...

Page 20: ...or when opening Anti clamp sensor when closing 24 Anti collision open YELLOW BROWN BLACK RED 23 Anti collision close YELLOW BROWN BLACK RED 12V red 17 22 GND 22 GND 20 24V NO COM GND 24V NO COM GND 24V 22 GND 22 GND 20 24V Anti clamp sensor when opening Anti clamp sensor when closing 24 Anti collision open RED PINK BROWN WHITE RED PINK BROWN WHITE 23 Anti collision close Electro TOP SENSOR IN 15 7...

Page 21: ...m green to red and turn to green again attention Please hold the learning button when you delete the remote memory Wireless push button Added and deleted wireless push button is the same as remote Please check de DIP switch if t s the same as shown on the image during setting process 1 Receiver has been built in 2 Exit only function Connect outside sensor or button to terminal Open B Connect to in...

Page 22: ...4 5 2 obstacle detection optimized for exterior wind loads 13 1 2 3 4 5 2 holding force closed 14 1 2 3 4 5 3 anti collision force 15 5 30 15 auto learning speed 16 0 1 2 10 4 working interval between master and slave door 0 1s 1 0 1s on master door the setting is working when closing on slave door the setting is working when opening 8 LED DISPLAY FEEDBACK LED DISPLAY DETAILS Dr11 No problem Dr12 ...

Page 23: ...buffer speed when opening closing is too fast slow down the buffer speed when opening closing stopper is loosen fix the stopper door does not work no power check the power switch connection terminal from motor to controller connect the power learning speed is too slow speed up the learning speed door is locked check whether the door is locked unlock the door obstacle in the pull bar guide check th...

Page 24: ...www jnf pt 68 72 NOTAS NOTES ...

Reviews: