UM-1097
Revision B
79
5.4
Bump Test Procedure
Note: A bump test, when performed correctly, is meant to check both sensor and alarm
functionality. This results in expected alarms, and proper precautions should be taken.
Also known as a functionality test, a bump test is not meant to test the accuracy of the detector, and no
calibration settings are changed during the test.
To perform a bump test, briefly expose the sensor to a gas of known concentration (above the Low Alarm
set point), and check to ensure the display reading increases to a value within tolerance of the
concentration applied and check for alarm actuation. If the sensor does not perform as expected, RC
Systems recommends performing a routine calibration and/or replacing the sensor. If the alarm does not
perform as expected check the detector’s alarm settings.
!
Summary of Contents for ViewSmart 1600+
Page 77: ...UM 1097 Revision B 67 4 7 5 4 Programmable Relays Figure 47 Webpage Programmable Relays Menu...
Page 78: ...UM 1097 Revision B 68 4 7 5 5 System Configuration Figure 48 Webpage System Configuration Menu...
Page 134: ...UM 1097 Revision B 124 Appendix 4 Menu Navigation...
Page 141: ...UM 1097 Revision B 131 Wireless Options and Accessories Expansion Options...