Operator Manual
Raytheon Anschütz GmbH
Germany
R
SYNAPSIS ECDIS
14--5
4343DOC020102
Edition: January 2016
An alert escalation situation can only be considered if a Bridge Navigation Watch
Alarm System (BNWAS) is connected to the INS.
The user is hereby forced to acknowledge an alarm within a given time window
(e.g. 60 seconds). If this time window is exceeded, an emergency call is trigge-
red. The system alarm escalation time is editable in Conning or Service Tool and
affects all alarms. The following (standard) procedure applies for the handling of
warnings. A warning that is not acknowledged is declared as an alarm after 60
seconds. If this alarm is also not acknowlged within further 60 seconds, an
emergency call is triggered.
Apart from the alert escalation, the SYNAPSIS INS also supports the resetting of
the BNWAS watch alarm by expedient operations in the ECDIS. If the navigator
works with the ECDIS, the watch alarm of the BNWAS is reset.
The expedient operation must take place at a console from which the user has
the ship and its surroundings in his sights (PROPER LOOKOUT).
Summary of Contents for SYNAPSIS ECDIS
Page 61: ...Operator Manual 2 34 4343DOC020102 Edition January 2016 Intentionally left blank ...
Page 67: ...Operator Manual 3 6 4343DOC020102 Edition January 2016 Intentionally left blank ...
Page 289: ...Operator Manual 8 78 4343DOC020102 Edition November 2019 Intentionally left blank ...
Page 290: ...Operator Manual 8 78 4343DOC020102 Edition January 2016 Intentionally left blank ...
Page 318: ...Operator Manual 10 8 4343DOC020102 Edition January 2016 Intentionally left blank ...
Page 396: ...Operator Manual 13 2 4343DOC020102 Edition January 2016 Figure 13 2 About ECDIS ...
Page 404: ...Operator Manual 14 8 4343DOC020102 Edition January 2016 Intentionally left blank ...
Page 408: ...Operator Manual 15 4 4343DOC020102 Edition January 2016 Intentionally left blank ...