Operator Manual
14--4
4343DOC020102
Edition: January 2016
Alert Escalation
Warnings have to possible escalation behaviours:
-- Repeat as warning Warning (audible signal) is repeated.
-- Escalate to alarm
Warning escalates to prority alarm.
Warning escalation is performed after configured warning escalation time.
The following list shows all warnings that will be repeated as warning and all
alarms that will not be escalated to BNWAS. All other warnings mentioned in this
manual will be escalated to alarm. All other alarms will be escalated to BNWAS.
Warnings repeated as warning:
-- Switch to valid speed source
-- Speed sensor valid
-- CM93/3 chart license will expire
-- Autopilot not ready
-- Autopilot not enough waypoints
-- Autopilot init error
The following list shows all alarms that will not be escalated to BNWAS. All other
alarms will be escalated to BNWAS.
Alarms that are not escalated to BNWAS:
-- Track control edition mismatch
-- Demo version: not for navigation
-- Tender alert
-- Tender man over board
-- Tender lost
-- Tender out of range
Summary of Contents for SYNAPSIS ECDIS
Page 61: ...Operator Manual 2 34 4343DOC020102 Edition January 2016 Intentionally left blank ...
Page 67: ...Operator Manual 3 6 4343DOC020102 Edition January 2016 Intentionally left blank ...
Page 289: ...Operator Manual 8 78 4343DOC020102 Edition November 2019 Intentionally left blank ...
Page 290: ...Operator Manual 8 78 4343DOC020102 Edition January 2016 Intentionally left blank ...
Page 318: ...Operator Manual 10 8 4343DOC020102 Edition January 2016 Intentionally left blank ...
Page 396: ...Operator Manual 13 2 4343DOC020102 Edition January 2016 Figure 13 2 About ECDIS ...
Page 404: ...Operator Manual 14 8 4343DOC020102 Edition January 2016 Intentionally left blank ...
Page 408: ...Operator Manual 15 4 4343DOC020102 Edition January 2016 Intentionally left blank ...