MT5 Multi-Tracer Operating Manual
page 75
11. Maintenance
11.1. MT5 Controller
The MT5 Controller is essentially maintenance free. However, a low velocity fan is
internally located that functions to minimize thermal gradients and reduce measurement
errors due to thermal-electric effects. Raydec recommends examining this fan once a
year to confirm that it is still operating. Failure of this fan is not anticipated during the life
of the equipment.
To examine this fan, remove the top cover of the control unit. It is not necessary to
unplug the AC power or signal connections to perform this visual inspection. The unit
must be kept powered to examine the operation of the fan. The fan is located to one
side. Simply verify that the fan is rotating.
Warning: Do not stick hands, tools or any other objects inside the unit. The
AC power supply has potentially harmful or fatal voltage levels. Take great
care to avoid contact with ANY circuitry inside the controller while making
this visual inspection.
11.1.1.
MT5 Load Unit
The MT5 Load Unit moves a large volume of air to dissipate the energy of the
connected PV modules. Depending on the operating environment, the fan intake air
filters may require periodic cleaning or replacement. These filters are on the outside of
the load unit and may be removed by unsnapping the filter guard. The filter material
may be cleaned with water.
These filters are inexpensive and readily available. See Appendix D -
“Replaceable
Parts” for the specific information on this filter. How frequently these filters need
cleaning and replacing depends heavily on the air quality.