MT5 Multi-Tracer Operating Manual
page 45
MT5 automatically creates a new file every day and automatically appends new data to
this file throughout the day.
The MTD file is a comma delineated, text file that can be imported into programs such
as Microsoft Excel for data viewing or additional processing.
5.1.2. Load Mode
Each PV module load operates independently from the other loads. There are three
operating conditions for a load:
1) Off
2) Peak-Power Track
3) Fixed Voltage
The most common setting is to operate the module at its peak-power point. The MT5
continuously regulates the load to hold the module near its peak-power operating
voltage. While it is possible to set each module’s load mode separately, it is often
simpler to set all loads to peak-power track
using the “Global” settings. Refer to section
“Global Load & IV Curve Control” for details on global load settings.
Note: It can take some time for the power tracking algorithm to converge, but tracking
typically begins within 30 seconds.