Manual No. 016-0159-925 Rev. F
33
Initial Startup & Console Programming
Valve Cal
Press the VALVE CAL button to display the currently programmed calibration value used to adjust the control
valve and keep product application on the target rate. This value sets control characteristics such as speed
and reaction of the various control valves. For details on setting or adjusting this value for a specific control
valve, refer to the
Note:
If the dual loop control feature is enabled, the valve cal value will be replaced with flow cal. Refer
to the Dual Loop Control (PWM Valves Only) section on page 43 for information on the dual loop
control feature or the Dual Loop Control Mode Settings section on page 57 for information on
configuring or adjusting the dual loop control settings.
Rate Cal
Press the RATE CAL button to display the currently programmed rate in gallons per acre (liters per hectare).
This is the target rate for product application.
Self Test
Press the SELF TEST button to display a test speed for checking or troubleshooting the product control
system.
Press and hold the SELF TEST button to view the SCS console initial programming values and settings. If the
SELFT TEST button is held for 12 seconds, the controller will stop scrolling and allow the operator to step
through the various settings and enter new values if desired.
Function Keys
The function keys display current application information. This information may also be helpful in calibrating,
fine tuning, or testing the controller or product control system. The totalizer buttons can be reset at any time.
Total Area
Pressing TOTAL AREA displays the total area covered.
Total Volume
Pressing TOTAL VOLUME displays the total volume applied.
Field Area
Pressing FIELD AREA displays the field area covered.
Field Volume
Pressing FIELD VOLUME displays the total volume applied to a field.
Distance
To display the SCS console odometer, displayed in feet or meters, press DISTANCE.
Note:
This reading is also useful when calibrating or fine tuning the speed cal.