33
Versione n.0 (09/95) Rev. n.3 (04/00)
R200 - R200I
9.
TROUBLESHOOTING TABLE
This table facilitates identification of the cause of the defect. Users are encouraged to contact technical service without delay to
obtain instructions on how to repair and/or adjust the equipment safely.
RAVAGLIOLI S.p.A. shall not be liable for injury to people or animals or damage to property in the event the equipment is serviced,
repaired, maintained or operated by unauthorised persons and/or unqualified personnel.
PROBLEMS
CAUSES
REMEDIES
ON button of play
tester pressed but
nothing happens
a)
b)
c)
d)
e)
Main switch in position 0 .
Fuse for transformer or main safety
fuses broken.
Electrical system, failure.
Electronic card, failure.
Keyboar, failure.
a)
b)
c)
d)
e)
Turn switch to 1
Replace broken fuses. If a fuse breaks
again, identify the causes of the
breakage.
Check that connections and
components are working properly.
Replace electronic card.
Replace keyboard.
Play tester does not
work (light lit)
a)
b)
c)
Electronic card, failure.
Solenoid valve blocked in closing
position.
Pump suction filter blocked.
a)
b)
c)
Replace electronic card.
Reset solenoid valve.
Clean filter.
With the play tester off,
the light does not come
on when the play tester
operation button is
pressed
a)
b)
c)
d)
e)
f)
Main switch in position 0 .
Fuse for transformer or main safety
fuses broken.
Electrical system, failure.
Electronic card, failure.
Keyboar, failure..
Bulb broken.
a)
b)
c)
d)
e)
f)
Turn switch to 1 .
Replace broken fuses. If a fuse breaks
again, identify the causes of the
breakage.
Check that connections and
components are working properly.
Replace electronic card.
Replace keyboard.
Replace bulb.
Play tester operation
button pressed, but the
plates do not move
correctly
a)
b)
c)
d)
e)
f)
Keyboar, failure.
Electronic card, failure.
Calibration valve not working properly.
Worn or damaged pump.
Pump suction filter partially blocked.
Solenoid valve blocked.
a)
b)
c)
d)
e)
f)
Replace keyboard.
Replace electronic card.
Ask dealer for technical assistance.
Check that the pump is working
properly and replace if necessary.
Clean the filter.
Reset solenoid valve.
When the OFF button
is pressed, the play
tester or light do not
go off
a)
b)
Keyboar, failure.
Electronic card, failure.
a)
b)
Replace keyboard.
Replace electronic card.